Zigbee heating valve follow check improved, battery check added
Esse commit está contido em:
pai
4fb01e2f93
commit
33042e3f3c
1
check_z_heat_vlv_battery
Link simbólico
1
check_z_heat_vlv_battery
Link simbólico
@ -0,0 +1 @@
|
||||
check_z_heat_vlv_follow
|
@ -7,7 +7,7 @@ import time
|
||||
from z_server import config
|
||||
from z_server import tcp_socket
|
||||
from z_server.z_protocol import server as client_prot
|
||||
from z_server.z_protocol import DID_FOLLOWS_HEATING_SETPOINT
|
||||
from z_server.z_protocol import DID_FOLLOWS_HEATING_SETPOINT, DID_BATTERY_LEVEL
|
||||
from z_server import socket_protocol
|
||||
import sys
|
||||
|
||||
@ -30,7 +30,14 @@ if __name__ == '__main__':
|
||||
"roo": args.roo,
|
||||
"fun": "FUN_HEA" # <-- Const, because script is for heat_vlv only
|
||||
}
|
||||
sp.send(socket_protocol.SID_READ_REQUEST, DID_FOLLOWS_HEATING_SETPOINT, data)
|
||||
#
|
||||
sp_data = sp.receive(socket_protocol.SID_READ_RESPONSE, DID_FOLLOWS_HEATING_SETPOINT).get_data()
|
||||
if sys.argv[0].endswith('check_z_heat_vlv_follow'):
|
||||
sp.send(socket_protocol.SID_READ_REQUEST, DID_FOLLOWS_HEATING_SETPOINT, data)
|
||||
sp_data = sp.receive(socket_protocol.SID_READ_RESPONSE, DID_FOLLOWS_HEATING_SETPOINT).get_data()
|
||||
elif sys.argv[0].endswith('check_z_heat_vlv_battery'):
|
||||
sp.send(socket_protocol.SID_READ_REQUEST, DID_BATTERY_LEVEL, data)
|
||||
sp_data = sp.receive(socket_protocol.SID_READ_RESPONSE, DID_BATTERY_LEVEL).get_data()
|
||||
else:
|
||||
sys.stderr.write('No action for command called "%s"\n' % sys.argv[0])
|
||||
sys.exit(100)
|
||||
nagios.Nagios().exit(**sp_data)
|
@ -14,6 +14,10 @@ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__)
|
||||
class base(object):
|
||||
FOLLOW_REQUEST_WARNING = 5 # Seconds, till warning comes up, if device does not follow the command
|
||||
FOLLOW_REQUEST_ERROR = 60 # Seconds, till error comes up, if device does not follow the command
|
||||
FOLLOW_KEYS = ["current_heating_setpoint", ]
|
||||
#
|
||||
BATTERY_LVL_WARNING = 10
|
||||
BATTERY_LVL_ERROR = 5
|
||||
|
||||
def __init__(self, mqtt_client: mqtt.mqtt_client, topic):
|
||||
self.topic = topic
|
||||
@ -23,6 +27,8 @@ class base(object):
|
||||
#
|
||||
self.__target_storage__ = {}
|
||||
self.__state_storage__ = {}
|
||||
#
|
||||
self.battery = None
|
||||
|
||||
def __rx__(self, client, userdata, message):
|
||||
pass
|
||||
@ -38,21 +44,37 @@ class base(object):
|
||||
logger.debug("Device state identified: %s: %s", key, repr(value))
|
||||
|
||||
def status(self, key):
|
||||
tm_s, value_s = self.__state_storage__.get(key, (0, None))
|
||||
try:
|
||||
tm_t, value_t = self.__target_storage__[key]
|
||||
except KeyError:
|
||||
if value_s is not None:
|
||||
return {"status": nagios.Nagios.WARNING, "msg": "Current temperature setpoint %.1f°C (age=%.1fs), but never received a setpoint" % (value_s, time.time()-tm_s)}
|
||||
return {"status": nagios.Nagios.UNKNOWN, "msg": "Device exists, but no data received or unknown monitoring"}
|
||||
else:
|
||||
tm = time.time()
|
||||
dt = tm - tm_t
|
||||
if value_t != value_s and dt > self.FOLLOW_REQUEST_ERROR:
|
||||
return {"status": nagios.Nagios.ERROR, "msg": "Requested setpoint unequal valve setpoint since %.1fs" % dt}
|
||||
elif value_t != value_s and dt > self.FOLLOW_REQUEST_WARNING:
|
||||
return {"status": nagios.Nagios.WARNING, "msg": "Requested setpoint unequal valve setpoint since %.1fs" % dt}
|
||||
return {"status": nagios.Nagios.OK, "msg": "Requested setpoint equal valve setpoint"}
|
||||
#
|
||||
# FOLLOW SETPOINT
|
||||
#
|
||||
if key in self.FOLLOW_KEYS:
|
||||
tm_s, value_s = self.__state_storage__.get(key, (0, None))
|
||||
try:
|
||||
tm_t, value_t = self.__target_storage__[key]
|
||||
except KeyError:
|
||||
if value_s is not None:
|
||||
return {"status": nagios.Nagios.WARNING, "msg": "Current temperature setpoint %.1f°C (age=%.1fs), but never received a setpoint" % (value_s, time.time()-tm_s)}
|
||||
return {"status": nagios.Nagios.UNKNOWN, "msg": "Device exists, but no data received or unknown monitoring"}
|
||||
else:
|
||||
tm = time.time()
|
||||
dt = tm - tm_t
|
||||
if value_t != value_s and dt > self.FOLLOW_REQUEST_ERROR:
|
||||
return {"status": nagios.Nagios.ERROR, "msg": "Requested setpoint unequal valve setpoint since %.1f°C (age=%.1fs)" % (value_s, time.time()-tm_s)}
|
||||
elif value_t != value_s and dt > self.FOLLOW_REQUEST_WARNING:
|
||||
return {"status": nagios.Nagios.WARNING, "msg": "Requested setpoint unequal valve setpoint since %.1f°C (age=%.1fs)" % (value_s, time.time()-tm_s)}
|
||||
return {"status": nagios.Nagios.OK, "msg": "Requested setpoint equal valve setpoint %.1f°C (age=%.1fs)" % (value_s, time.time()-tm_s)}
|
||||
#
|
||||
# BATTERY
|
||||
#
|
||||
elif key == "battery":
|
||||
if self.battery is None:
|
||||
return {"status": nagios.Nagios.UNKNOWN, "msg": "Device exists, but no data received or unknown monitoring"}
|
||||
elif self.battery < self.BATTERY_LVL_ERROR:
|
||||
return {"status": nagios.Nagios.ERROR, "msg": "Battery level critical low (%.1f%%)" % self.battery}
|
||||
elif self.battery < self.BATTERY_LVL_WARNING:
|
||||
return {"status": nagios.Nagios.WARNING, "msg": "Battery level low (%.1f%%)" % self.battery}
|
||||
else:
|
||||
return {"status": nagios.Nagios.OK, "msg": "Battery okay (%.1f%%)" % self.battery}
|
||||
|
||||
|
||||
class group(object):
|
||||
@ -95,6 +117,8 @@ class brennenstuhl_heatingvalve(base):
|
||||
self.target("current_heating_setpoint", payload["current_heating_setpoint"])
|
||||
if message.topic == self.topic:
|
||||
self.state("current_heating_setpoint", payload["current_heating_setpoint"])
|
||||
if "battery" in payload and message.topic == self.topic:
|
||||
self.battery = payload["battery"]
|
||||
|
||||
|
||||
class silvercrest_powerplug(base):
|
||||
|
@ -3,6 +3,7 @@ import socket_protocol
|
||||
# from devdi.topic import topic_by_props
|
||||
|
||||
DID_FOLLOWS_HEATING_SETPOINT = 'current_heating_setpoint'
|
||||
DID_BATTERY_LEVEL = 'battery'
|
||||
|
||||
|
||||
class server(socket_protocol.pure_json_protocol):
|
||||
@ -15,9 +16,10 @@ class server(socket_protocol.pure_json_protocol):
|
||||
# DID_FOLLOWS_HEATING_SETPOINT, 'current_heating_setpoint')
|
||||
#
|
||||
if not self.__comm_inst__.IS_CLIENT:
|
||||
self.register_callback(socket_protocol.SID_READ_REQUEST, DID_FOLLOWS_HEATING_SETPOINT, self.follow_heating_setpoint)
|
||||
self.register_callback(socket_protocol.SID_READ_REQUEST, DID_FOLLOWS_HEATING_SETPOINT, self.device_status)
|
||||
self.register_callback(socket_protocol.SID_READ_REQUEST, DID_BATTERY_LEVEL, self.device_status)
|
||||
|
||||
def follow_heating_setpoint(self, msg):
|
||||
def device_status(self, msg):
|
||||
if msg.get_status() == socket_protocol.STATUS_OKAY:
|
||||
try:
|
||||
dev = self.__devices__.get_str(**msg.get_data())
|
||||
|
Carregando…
x
Referência em uma nova issue