Fix and reduction of undervoltage only
This commit is contained in:
parent
12f9e57ea7
commit
9bcf1fc486
@ -4,6 +4,19 @@ import argparse
|
||||
import nagios
|
||||
import subprocess
|
||||
|
||||
"""
|
||||
Bit Hex Value Meaning
|
||||
0 1 Under-voltage detected
|
||||
1 2 ARM frequency has been caped
|
||||
2 4 Currently throttled
|
||||
3 8 Soft temperature limit is active
|
||||
16 1000 Under-voltage has occurred
|
||||
17 2000 ARM frequency capping has occurred
|
||||
18 4000 Throttling has occurred
|
||||
19 8000 Soft temperature limit has occurred
|
||||
|
||||
Bit16+ are resetted with a reboot (only)
|
||||
"""
|
||||
|
||||
if __name__ == "__main__":
|
||||
throttled = subprocess.check_output(['vcgencmd', 'get_throttled']).decode('utf-8')
|
||||
@ -12,15 +25,15 @@ if __name__ == "__main__":
|
||||
tval = int(tval, 16)
|
||||
except ValueError:
|
||||
tval = None
|
||||
else:
|
||||
tval &= 0x3fff # remove the values which are only resetted with a reboot
|
||||
#
|
||||
n = nagios.Nagios()
|
||||
#
|
||||
if tval is None:
|
||||
status = n.UNKNOWN
|
||||
elif tval & 0x4000 != 0:
|
||||
elif tval & 0x1 != 0:
|
||||
status = n.ERROR
|
||||
elif tval != 0:
|
||||
status = n.WARNING
|
||||
else:
|
||||
status = n.OK
|
||||
#
|
||||
|