@@ -2,13 +2,13 @@
|
2
|
2
|
# -*- coding: UTF-8 -*-
|
3
|
3
|
#
|
4
|
4
|
|
5
|
|
-#TODO: Zyklischer reconnect versuch (ggf. inkl. herstellen der Schnittstelle für ein reconnect beim tcp_client)
|
6
|
|
-
|
7
|
5
|
import config
|
8
|
|
-import rpi_envsens as envsens
|
|
6
|
+from rpi_envsens.dht import dht_22
|
|
7
|
+from rpi_envsens.bmp import bmp_180
|
9
|
8
|
import garage_protocol
|
10
|
9
|
import gui
|
11
|
10
|
import logging
|
|
11
|
+import numbers
|
12
|
12
|
import os
|
13
|
13
|
import report
|
14
|
14
|
import task
|
|
@@ -25,16 +25,32 @@ class WetationFrameProt(gui.Wetation):
|
25
|
25
|
PROT_ID_IN = 1
|
26
|
26
|
PROT_ID_OUT = 2
|
27
|
27
|
ALL_PROT_IDS = [PROT_ID_GARAGE, PROT_ID_IN, PROT_ID_OUT, ]
|
28
|
|
- SLOW_PROT_IDS = [PROT_ID_IN, PROT_ID_OUT, ]
|
29
|
|
- FAST_PROT_IDS = [PROT_ID_GARAGE, ]
|
|
28
|
+
|
|
29
|
+ PROT_IPS = {
|
|
30
|
+ PROT_ID_GARAGE: config.server_garage_ip,
|
|
31
|
+ PROT_ID_IN: config.server_in_ip,
|
|
32
|
+ PROT_ID_OUT: config.server_out_ip,
|
|
33
|
+ }
|
|
34
|
+
|
|
35
|
+ PROT_PORTS = {
|
|
36
|
+ PROT_ID_GARAGE: config.server_garage_port,
|
|
37
|
+ PROT_ID_IN: config.server_in_port,
|
|
38
|
+ PROT_ID_OUT: config.server_out_port,
|
|
39
|
+ }
|
|
40
|
+
|
|
41
|
+ PROT_SECRETS = {
|
|
42
|
+ PROT_ID_GARAGE: config.server_garage_secret,
|
|
43
|
+ PROT_ID_IN: config.server_in_secret,
|
|
44
|
+ PROT_ID_OUT: config.server_out_secret,
|
|
45
|
+ }
|
30
|
46
|
|
31
|
|
- REQUEST_MSGS = {
|
32
|
|
- PROT_ID_GARAGE: [
|
33
|
|
- {
|
34
|
|
- 'service_id': garage_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
35
|
|
- 'data_id': garage_protocol.my_base_protocol_tcp.GATE_POSITION,
|
36
|
|
- },
|
37
|
|
- ],
|
|
47
|
+ PROT_CLASSES = {
|
|
48
|
+ PROT_ID_GARAGE: garage_protocol.my_base_protocol_tcp,
|
|
49
|
+ PROT_ID_IN: wetation_protocol.my_base_protocol_tcp,
|
|
50
|
+ PROT_ID_OUT: wetation_protocol.my_base_protocol_tcp,
|
|
51
|
+ }
|
|
52
|
+
|
|
53
|
+ REQUEST_MSGS_SLOW = {
|
38
|
54
|
PROT_ID_IN: [
|
39
|
55
|
{
|
40
|
56
|
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
|
@@ -49,160 +65,169 @@ class WetationFrameProt(gui.Wetation):
|
49
|
65
|
],
|
50
|
66
|
}
|
51
|
67
|
|
|
68
|
+ REQUEST_MSGS_FAST = {
|
|
69
|
+ PROT_ID_GARAGE: [
|
|
70
|
+ {
|
|
71
|
+ 'service_id': garage_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
|
72
|
+ 'data_id': garage_protocol.my_base_protocol_tcp.GATE_POSITION,
|
|
73
|
+ },
|
|
74
|
+ ],
|
|
75
|
+ }
|
|
76
|
+
|
52
|
77
|
|
53
|
78
|
def __init__(self, *args, **kwds):
|
|
79
|
+ self.__min_temp_in__ = None
|
|
80
|
+ self.__min_temp_out__ = None
|
|
81
|
+ self.__max_temp_in__ = None
|
|
82
|
+ self.__max_temp_out__ = None
|
54
|
83
|
self.__prot__ = {}
|
55
|
|
- self.no_data = {
|
56
|
|
- self.PROT_ID_GARAGE: self.update_gate_position,
|
57
|
|
- self.PROT_ID_IN: self.update_current_env_data_in,
|
58
|
|
- self.PROT_ID_OUT: self.update_current_env_data_out,
|
59
|
|
- }
|
60
|
84
|
gui.Wetation.__init__(self, *args, **kwds)
|
|
85
|
+ self.in_temperature_min.Bind(wx.EVT_LEFT_DOWN, self.reset_in_temp_minmax_evt)
|
|
86
|
+ self.in_temperature_max.Bind(wx.EVT_LEFT_DOWN, self.reset_in_temp_minmax_evt)
|
|
87
|
+ self.out_temperature_min.Bind(wx.EVT_LEFT_DOWN, self.reset_out_temp_minmax_evt)
|
|
88
|
+ self.out_temperature_max.Bind(wx.EVT_LEFT_DOWN, self.reset_out_temp_minmax_evt)
|
61
|
89
|
self.ShowFullScreen(config.FULL_SCREEN)
|
62
|
90
|
|
63
|
91
|
self.__init_communication__()
|
|
92
|
+
|
64
|
93
|
self.__task_1s__ = task.periodic(1, self.__task_1s_callback__)
|
65
|
94
|
self.__task_10s__ = task.periodic(10, self.__task_10s_callback__)
|
66
|
95
|
self.__task_60s__ = task.periodic(60, self.__task_60s_callback__)
|
67
|
96
|
|
68
|
|
- def __init_protocol__(self, prot_id, ip, port, prot_class, secret):
|
69
|
|
- c_tcp = tcp_socket.tcp_client_stp(ip, port, rx_log_lvl=logging.DEBUG)
|
70
|
|
- self.__prot__[prot_id] = prot_class(c_tcp, secret)
|
71
|
|
- if config.server_garage_secret is not None:
|
72
|
|
- self.__prot__[prot_id].authentificate()
|
73
|
|
-
|
74
|
97
|
def __init_communication__(self):
|
75
|
98
|
#
|
76
|
99
|
# Start TCP-Clients
|
77
|
|
- self.__init_protocol__(
|
78
|
|
- self.PROT_ID_GARAGE,
|
79
|
|
- config.server_garage_ip,
|
80
|
|
- config.server_garage_port,
|
81
|
|
- garage_protocol.my_base_protocol_tcp,
|
82
|
|
- config.server_garage_secret
|
83
|
|
- )
|
84
|
|
- self.__prot__[self.PROT_ID_GARAGE].register_callback(garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__garage_data__)
|
85
|
|
-
|
86
|
|
- self.__init_protocol__(
|
87
|
|
- self.PROT_ID_IN,
|
88
|
|
- config.server_in_ip,
|
89
|
|
- config.server_in_port,
|
90
|
|
- wetation_protocol.my_base_protocol_tcp,
|
91
|
|
- config.server_in_secret
|
92
|
|
- )
|
93
|
|
- self.__prot__[self.PROT_ID_IN].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__in_data__)
|
94
|
|
-
|
95
|
|
- self.__init_protocol__(
|
96
|
|
- self.PROT_ID_OUT,
|
97
|
|
- config.server_out_ip,
|
98
|
|
- config.server_out_port,
|
99
|
|
- wetation_protocol.my_base_protocol_tcp,
|
100
|
|
- config.server_out_secret
|
101
|
|
- )
|
102
|
|
- self.__prot__[self.PROT_ID_OUT].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__out_data__)
|
|
100
|
+ for prot_id in self.ALL_PROT_IDS:
|
|
101
|
+ logger.debug('Initiating communication channel for prot_id %d', prot_id)
|
|
102
|
+ c_tcp = tcp_socket.tcp_client_stp(self.PROT_IPS[prot_id], self.PROT_PORTS[prot_id], rx_log_lvl=logging.DEBUG)
|
|
103
|
+ self.__prot__[prot_id] = self.PROT_CLASSES[prot_id](c_tcp, secret=self.PROT_SECRETS[prot_id], auto_auth=True)
|
|
104
|
+ #
|
|
105
|
+ self.__prot__[prot_id].register_callback(None, None, self.__prot_resp_callbacks__, prot_id)
|
|
106
|
+
|
|
107
|
+ def __initiate_data_request__(self, rt, request_msgs):
|
|
108
|
+ for prot_id in request_msgs:
|
|
109
|
+ for request_msg in request_msgs.get(prot_id, []):
|
|
110
|
+ service_id = request_msg['service_id']
|
|
111
|
+ data_id = request_msg['data_id']
|
|
112
|
+ if self.__prot__[prot_id].connection_established():
|
|
113
|
+ logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
|
|
114
|
+ self.__prot__[prot_id].send(service_id, data_id, None)
|
|
115
|
+ else:
|
|
116
|
+ wx.CallAfter(self.__no_data__, prot_id, service_id + 1, data_id)
|
103
|
117
|
|
104
|
118
|
def __task_1s_callback__(self, rt):
|
105
|
119
|
# request data from fast prot ids
|
106
|
|
- self.__initiate_data_request__(rt, self.FAST_PROT_IDS)
|
|
120
|
+ self.__initiate_data_request__(rt, self.REQUEST_MSGS_FAST)
|
107
|
121
|
# set date and time
|
108
|
122
|
wx.CallAfter(self.update_time)
|
109
|
123
|
|
110
|
124
|
def __task_10s_callback__(self, rt):
|
111
|
125
|
# request data from slow prot ids
|
112
|
|
- self.__initiate_data_request__(rt, self.SLOW_PROT_IDS)
|
|
126
|
+ self.__initiate_data_request__(rt, self.REQUEST_MSGS_SLOW)
|
113
|
127
|
|
114
|
128
|
def __task_60s_callback__(self, rt):
|
115
|
129
|
# reconnect prots if needed
|
116
|
130
|
for prot_id in self.ALL_PROT_IDS:
|
117
|
|
- if not self.__prot__[prot_id].is_connected():
|
|
131
|
+ if not self.__prot__[prot_id].connected():
|
118
|
132
|
logger.debug("Trying to reconnect prot_id %d", prot_id)
|
119
|
133
|
self.__prot__[prot_id].reconnect()
|
120
|
134
|
|
121
|
|
- def __initiate_data_request__(self, rt, prot_ids):
|
122
|
|
- for prot_id in prot_ids:
|
123
|
|
- if self.__prot__[prot_id].is_connected():
|
124
|
|
- for request_msg in self.REQUEST_MSGS.get(prot_id, []):
|
125
|
|
- service_id = request_msg['service_id']
|
126
|
|
- data_id = request_msg['data_id']
|
127
|
|
- logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
|
128
|
|
- self.__prot__[prot_id].send(service_id, data_id, None)
|
129
|
|
- else:
|
130
|
|
- logger.debug('Resetting GUI for prot_id %d', prot_id)
|
131
|
|
- wx.CallAfter(self.no_data[prot_id], None)
|
132
|
|
-
|
133
|
|
- def __in_data__(self, msg):
|
134
|
|
- return self.__env_data__(msg, self.PROT_ID_IN)
|
135
|
|
-
|
136
|
|
- def __out_data__(self, msg):
|
137
|
|
- return self.__env_data__(msg, self.PROT_ID_OUT)
|
138
|
|
-
|
139
|
|
- def __env_data__(self, msg, prot_id):
|
140
|
|
- logger.debug('Received data for prot_id %d, service_id %d, data_id %d', prot_id, msg.get_service_id(), msg.get_data_id())
|
141
|
|
- if msg.get_status() == wetation_protocol.my_base_protocol_tcp.STATUS_OKAY:
|
142
|
|
- if msg.get_data_id() == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
143
|
|
- if prot_id == self.PROT_ID_IN:
|
144
|
|
- wx.CallAfter(self.update_current_env_data_in, msg)
|
145
|
|
- else:
|
146
|
|
- wx.CallAfter(self.update_current_env_data_out, msg)
|
147
|
|
- return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
148
|
|
- else:
|
149
|
|
- logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
|
135
|
+ def __validate_response_data__(self, prot_id, service_id, data_id, data):
|
|
136
|
+ rv = False
|
|
137
|
+ if prot_id == self.PROT_ID_GARAGE:
|
|
138
|
+ if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
|
139
|
+ rv = isinstance(data, numbers.Number)
|
|
140
|
+ elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
|
141
|
+ if data is True:
|
|
142
|
+ rv = True
|
|
143
|
+ elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
|
144
|
+ if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
|
145
|
+ rv = isinstance(data.get(dht_22.KEY_TEMPERATURE), numbers.Number) and isinstance(data.get(dht_22.KEY_HUMIDITY), numbers.Number) and isinstance(data.get(bmp_180.KEY_PRESSURE), numbers.Number)
|
|
146
|
+ if rv is False:
|
|
147
|
+ logger.warning("Validation failed for message: prot_id=%s, service_id=%s, data_id=%s, data=%s", repr(prot_id), repr(service_id), repr(data_id), repr(data))
|
|
148
|
+ return rv
|
|
149
|
+
|
|
150
|
+ def __prot_resp_callbacks__(self, msg, prot_id):
|
|
151
|
+ service_id = msg.get_service_id()
|
|
152
|
+ data_id = msg.get_data_id()
|
|
153
|
+ data = msg.get_data()
|
|
154
|
+ if self.__validate_response_data__(prot_id, service_id, data_id, data):
|
|
155
|
+ wx.CallAfter(self.__data__, prot_id, service_id, data_id, data)
|
150
|
156
|
return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
151
|
157
|
else:
|
152
|
|
- logger.error('Error, receiving environmental data! MSG_STATUS was %s with PROT_ID %d', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())), prot_id)
|
|
158
|
+ wx.CallAfter(self.__no_data__, prot_id, service_id, data_id)
|
153
|
159
|
return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
154
|
160
|
|
155
|
|
- def __garage_data__(self, msg):
|
156
|
|
- logger.debug('Received data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
157
|
|
- if msg.get_status() == garage_protocol.my_base_protocol_tcp.STATUS_OKAY:
|
158
|
|
- if msg.get_data_id() == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
159
|
|
- wx.CallAfter(self.update_gate_position, msg)
|
|
161
|
+ def __no_data__(self, prot_id, service_id, data_id):
|
|
162
|
+ if prot_id == self.PROT_ID_GARAGE:
|
|
163
|
+ if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
|
164
|
+ logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
|
165
|
+ self.heading_garage.Show(False)
|
|
166
|
+ self.gate_oc.Show(False)
|
|
167
|
+ self.gate_open.Show(False)
|
|
168
|
+ self.gate_position.Show(False)
|
|
169
|
+ self.gate_close.Show(False)
|
|
170
|
+ self.Layout()
|
|
171
|
+ return
|
|
172
|
+ elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
|
173
|
+ return
|
|
174
|
+ elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
|
175
|
+ if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
|
176
|
+ logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
|
177
|
+ txt_temperature = '-.- °C'
|
|
178
|
+ txt_humidity = '-.- %'
|
|
179
|
+ txt_pressure = '- hPa'
|
|
180
|
+ if prot_id == self.PROT_ID_IN:
|
|
181
|
+ self.in_temperature.SetLabel(txt_temperature)
|
|
182
|
+ self.in_humidity.SetLabel(txt_humidity)
|
|
183
|
+ self.in_pressure.SetLabel(txt_pressure)
|
|
184
|
+ else:
|
|
185
|
+ self.out_temperature.SetLabel(txt_temperature)
|
|
186
|
+ self.out_humidity.SetLabel(txt_humidity)
|
|
187
|
+ self.out_pressure.SetLabel(txt_pressure)
|
|
188
|
+ self.Layout()
|
|
189
|
+ return
|
|
190
|
+ logger.warning("Unknown response with no valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
|
191
|
+
|
|
192
|
+ def __data__(self, prot_id, service_id, data_id, data):
|
|
193
|
+ if prot_id == self.PROT_ID_GARAGE:
|
|
194
|
+ if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
|
195
|
+ self.heading_garage.Show(True)
|
|
196
|
+ self.gate_oc.Show(True)
|
|
197
|
+ self.gate_open.Show(True)
|
|
198
|
+ self.gate_position.Show(True)
|
|
199
|
+ self.gate_close.Show(True)
|
|
200
|
+ self.gate_position.SetValue(int(data * 100))
|
|
201
|
+ self.Layout()
|
160
|
202
|
return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
161
|
|
- else:
|
162
|
|
- logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
163
|
|
- else:
|
164
|
|
- logger.error('Error, receiving garage data! MSG_STATUS was %s', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())))
|
165
|
|
- return garage_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
166
|
|
-
|
167
|
|
-
|
168
|
|
- def update_current_env_data_in(self, msg):
|
169
|
|
- if msg is None:
|
170
|
|
- temperature = '-.-'
|
171
|
|
- humidity = '-.-'
|
172
|
|
- pressure = '-'
|
173
|
|
- else:
|
174
|
|
- env_data = msg.get_data()
|
175
|
|
- temperature = '%.1f' % env_data[envsens.KEY_TEMPERATURE]
|
176
|
|
- humidity = '%.1f' % env_data[envsens.KEY_HUMIDITY]
|
177
|
|
- pressure = '%.0f' % env_data[envsens.KEY_PRESSURE]
|
178
|
|
- self.in_temperature.SetLabel("%s °C" % temperature)
|
179
|
|
- self.in_humidity.SetLabel("%s %%" % humidity)
|
180
|
|
- self.in_pressure.SetLabel("%s hPa" % pressure)
|
181
|
|
- self.Layout()
|
182
|
|
-
|
183
|
|
- def update_current_env_data_out(self, msg):
|
184
|
|
- if msg is None:
|
185
|
|
- temperature = '-.-'
|
186
|
|
- humidity = '-.-'
|
187
|
|
- pressure = '-'
|
188
|
|
- else:
|
189
|
|
- env_data = msg.get_data()
|
190
|
|
- temperature = "%.1f" % env_data[envsens.KEY_TEMPERATURE]
|
191
|
|
- humidity = "%.1f" % env_data[envsens.KEY_HUMIDITY]
|
192
|
|
- pressure = "%.0f" % env_data[envsens.KEY_PRESSURE]
|
193
|
|
- self.out_temperature.SetLabel("%s °C" % temperature)
|
194
|
|
- self.out_humidity.SetLabel("%s %%" % humidity)
|
195
|
|
- self.out_pressure.SetLabel("%s hPa" % pressure)
|
196
|
|
- self.Layout()
|
197
|
|
-
|
198
|
|
- def update_gate_position(self, msg):
|
199
|
|
- self.heading_garage.Show(msg is not None)
|
200
|
|
- self.gate_oc.Show(msg is not None)
|
201
|
|
- self.gate_open.Show(msg is not None)
|
202
|
|
- self.gate_position.Show(msg is not None)
|
203
|
|
- self.gate_close.Show(msg is not None)
|
204
|
|
- if msg is not None:
|
205
|
|
- self.gate_position.SetValue(msg.get_data() * 100)
|
|
203
|
+ elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
|
204
|
+ return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
|
205
|
+ elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
|
206
|
+ if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
|
207
|
+ temp = data[dht_22.KEY_TEMPERATURE]
|
|
208
|
+ if prot_id == self.PROT_ID_IN:
|
|
209
|
+ if self.__max_temp_in__ is None or temp > self.__max_temp_in__:
|
|
210
|
+ self.__max_temp_in__ = temp
|
|
211
|
+ if self.__min_temp_in__ is None or temp < self.__min_temp_in__:
|
|
212
|
+ self.__min_temp_in__ = temp
|
|
213
|
+ wx.CallAfter(self.update_current_env_data, data, self.in_temperature, self.in_humidity, self.in_pressure, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
|
|
214
|
+ else:
|
|
215
|
+ if self.__max_temp_out__ is None or temp > self.__max_temp_out__:
|
|
216
|
+ self.__max_temp_out__ = temp
|
|
217
|
+ if self.__min_temp_out__ is None or temp < self.__min_temp_out__:
|
|
218
|
+ self.__min_temp_out__ = temp
|
|
219
|
+ wx.CallAfter(self.update_current_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
|
|
220
|
+ return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
|
221
|
+ logger.warning("Unknown response with valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
|
222
|
+ return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
|
223
|
+
|
|
224
|
+ def update_current_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
|
|
225
|
+ if isinstance(value_min, numbers.Number) and isinstance(value_max, numbers.Number):
|
|
226
|
+ temperature_min.SetLabel('%.1f' % value_min)
|
|
227
|
+ temperature_max.SetLabel('%.1f' % value_max)
|
|
228
|
+ temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE])
|
|
229
|
+ humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY])
|
|
230
|
+ pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE])
|
206
|
231
|
self.Layout()
|
207
|
232
|
|
208
|
233
|
def update_time(self):
|
|
@@ -210,11 +235,27 @@ class WetationFrameProt(gui.Wetation):
|
210
|
235
|
self.date.SetLabel(time.strftime("%d.%m.%Y"))
|
211
|
236
|
self.Layout()
|
212
|
237
|
|
213
|
|
- def gate_oc_evt(self, event): # wxGlade: Wetation.<event_handler>
|
|
238
|
+ def gate_oc_evt(self, event):
|
214
|
239
|
logger.debug("Gate open/close request")
|
215
|
240
|
self.__prot__[self.PROT_ID_GARAGE].send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
|
216
|
241
|
event.Skip()
|
217
|
242
|
|
|
243
|
+ def reset_in_temp_minmax_evt(self, event):
|
|
244
|
+ self.__min_temp_in__ = None
|
|
245
|
+ self.__max_temp_in__ = None
|
|
246
|
+ self.in_temperature_min.SetLabel("-.- °C")
|
|
247
|
+ self.in_temperature_max.SetLabel("-.- °C")
|
|
248
|
+ self.Layout()
|
|
249
|
+ event.Skip()
|
|
250
|
+
|
|
251
|
+ def reset_out_temp_minmax_evt(self, event):
|
|
252
|
+ self.__min_temp_out__ = None
|
|
253
|
+ self.__max_temp_out__ = None
|
|
254
|
+ self.out_temperature_min.SetLabel("-.- °C")
|
|
255
|
+ self.out_temperature_max.SetLabel("-.- °C")
|
|
256
|
+ self.Layout()
|
|
257
|
+ event.Skip()
|
|
258
|
+
|
218
|
259
|
def run(self):
|
219
|
260
|
self.__task_1s__.run()
|
220
|
261
|
self.__task_10s__.run()
|