New Functions and Restructuring
This commit is contained in:
parent
2e01d3b503
commit
0bb85004d0
3
.gitmodules
vendored
3
.gitmodules
vendored
@ -22,3 +22,6 @@
|
||||
[submodule "garage_protocol"]
|
||||
path = garage_protocol
|
||||
url = https://git.mount-mockery.de/application/garage_protocol.git
|
||||
[submodule "helpers"]
|
||||
path = helpers
|
||||
url = https://git.mount-mockery.de/pylib/helpers.git
|
||||
|
1
helpers
Submodule
1
helpers
Submodule
@ -0,0 +1 @@
|
||||
Subproject commit 1819df790c0784473480dffe9aca8ca774d46343
|
@ -1 +1 @@
|
||||
Subproject commit fd86c70c83f75bcbbfc60ed69a99252bd7fb62b9
|
||||
Subproject commit 5ffef8254a0a035bc11ccefbd19497dd3969ac10
|
299
smarthome.py
299
smarthome.py
@ -2,13 +2,13 @@
|
||||
# -*- coding: UTF-8 -*-
|
||||
#
|
||||
|
||||
#TODO: Zyklischer reconnect versuch (ggf. inkl. herstellen der Schnittstelle für ein reconnect beim tcp_client)
|
||||
|
||||
import config
|
||||
import rpi_envsens as envsens
|
||||
from rpi_envsens.dht import dht_22
|
||||
from rpi_envsens.bmp import bmp_180
|
||||
import garage_protocol
|
||||
import gui
|
||||
import logging
|
||||
import numbers
|
||||
import os
|
||||
import report
|
||||
import task
|
||||
@ -25,16 +25,32 @@ class WetationFrameProt(gui.Wetation):
|
||||
PROT_ID_IN = 1
|
||||
PROT_ID_OUT = 2
|
||||
ALL_PROT_IDS = [PROT_ID_GARAGE, PROT_ID_IN, PROT_ID_OUT, ]
|
||||
SLOW_PROT_IDS = [PROT_ID_IN, PROT_ID_OUT, ]
|
||||
FAST_PROT_IDS = [PROT_ID_GARAGE, ]
|
||||
|
||||
REQUEST_MSGS = {
|
||||
PROT_ID_GARAGE: [
|
||||
{
|
||||
'service_id': garage_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': garage_protocol.my_base_protocol_tcp.GATE_POSITION,
|
||||
},
|
||||
],
|
||||
PROT_IPS = {
|
||||
PROT_ID_GARAGE: config.server_garage_ip,
|
||||
PROT_ID_IN: config.server_in_ip,
|
||||
PROT_ID_OUT: config.server_out_ip,
|
||||
}
|
||||
|
||||
PROT_PORTS = {
|
||||
PROT_ID_GARAGE: config.server_garage_port,
|
||||
PROT_ID_IN: config.server_in_port,
|
||||
PROT_ID_OUT: config.server_out_port,
|
||||
}
|
||||
|
||||
PROT_SECRETS = {
|
||||
PROT_ID_GARAGE: config.server_garage_secret,
|
||||
PROT_ID_IN: config.server_in_secret,
|
||||
PROT_ID_OUT: config.server_out_secret,
|
||||
}
|
||||
|
||||
PROT_CLASSES = {
|
||||
PROT_ID_GARAGE: garage_protocol.my_base_protocol_tcp,
|
||||
PROT_ID_IN: wetation_protocol.my_base_protocol_tcp,
|
||||
PROT_ID_OUT: wetation_protocol.my_base_protocol_tcp,
|
||||
}
|
||||
|
||||
REQUEST_MSGS_SLOW = {
|
||||
PROT_ID_IN: [
|
||||
{
|
||||
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
@ -49,160 +65,169 @@ class WetationFrameProt(gui.Wetation):
|
||||
],
|
||||
}
|
||||
|
||||
REQUEST_MSGS_FAST = {
|
||||
PROT_ID_GARAGE: [
|
||||
{
|
||||
'service_id': garage_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': garage_protocol.my_base_protocol_tcp.GATE_POSITION,
|
||||
},
|
||||
],
|
||||
}
|
||||
|
||||
|
||||
def __init__(self, *args, **kwds):
|
||||
self.__min_temp_in__ = None
|
||||
self.__min_temp_out__ = None
|
||||
self.__max_temp_in__ = None
|
||||
self.__max_temp_out__ = None
|
||||
self.__prot__ = {}
|
||||
self.no_data = {
|
||||
self.PROT_ID_GARAGE: self.update_gate_position,
|
||||
self.PROT_ID_IN: self.update_current_env_data_in,
|
||||
self.PROT_ID_OUT: self.update_current_env_data_out,
|
||||
}
|
||||
gui.Wetation.__init__(self, *args, **kwds)
|
||||
self.in_temperature_min.Bind(wx.EVT_LEFT_DOWN, self.reset_in_temp_minmax_evt)
|
||||
self.in_temperature_max.Bind(wx.EVT_LEFT_DOWN, self.reset_in_temp_minmax_evt)
|
||||
self.out_temperature_min.Bind(wx.EVT_LEFT_DOWN, self.reset_out_temp_minmax_evt)
|
||||
self.out_temperature_max.Bind(wx.EVT_LEFT_DOWN, self.reset_out_temp_minmax_evt)
|
||||
self.ShowFullScreen(config.FULL_SCREEN)
|
||||
|
||||
self.__init_communication__()
|
||||
|
||||
self.__task_1s__ = task.periodic(1, self.__task_1s_callback__)
|
||||
self.__task_10s__ = task.periodic(10, self.__task_10s_callback__)
|
||||
self.__task_60s__ = task.periodic(60, self.__task_60s_callback__)
|
||||
|
||||
def __init_protocol__(self, prot_id, ip, port, prot_class, secret):
|
||||
c_tcp = tcp_socket.tcp_client_stp(ip, port, rx_log_lvl=logging.DEBUG)
|
||||
self.__prot__[prot_id] = prot_class(c_tcp, secret)
|
||||
if config.server_garage_secret is not None:
|
||||
self.__prot__[prot_id].authentificate()
|
||||
|
||||
def __init_communication__(self):
|
||||
#
|
||||
# Start TCP-Clients
|
||||
self.__init_protocol__(
|
||||
self.PROT_ID_GARAGE,
|
||||
config.server_garage_ip,
|
||||
config.server_garage_port,
|
||||
garage_protocol.my_base_protocol_tcp,
|
||||
config.server_garage_secret
|
||||
)
|
||||
self.__prot__[self.PROT_ID_GARAGE].register_callback(garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__garage_data__)
|
||||
for prot_id in self.ALL_PROT_IDS:
|
||||
logger.debug('Initiating communication channel for prot_id %d', prot_id)
|
||||
c_tcp = tcp_socket.tcp_client_stp(self.PROT_IPS[prot_id], self.PROT_PORTS[prot_id], rx_log_lvl=logging.DEBUG)
|
||||
self.__prot__[prot_id] = self.PROT_CLASSES[prot_id](c_tcp, secret=self.PROT_SECRETS[prot_id], auto_auth=True)
|
||||
#
|
||||
self.__prot__[prot_id].register_callback(None, None, self.__prot_resp_callbacks__, prot_id)
|
||||
|
||||
self.__init_protocol__(
|
||||
self.PROT_ID_IN,
|
||||
config.server_in_ip,
|
||||
config.server_in_port,
|
||||
wetation_protocol.my_base_protocol_tcp,
|
||||
config.server_in_secret
|
||||
)
|
||||
self.__prot__[self.PROT_ID_IN].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__in_data__)
|
||||
|
||||
self.__init_protocol__(
|
||||
self.PROT_ID_OUT,
|
||||
config.server_out_ip,
|
||||
config.server_out_port,
|
||||
wetation_protocol.my_base_protocol_tcp,
|
||||
config.server_out_secret
|
||||
)
|
||||
self.__prot__[self.PROT_ID_OUT].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__out_data__)
|
||||
def __initiate_data_request__(self, rt, request_msgs):
|
||||
for prot_id in request_msgs:
|
||||
for request_msg in request_msgs.get(prot_id, []):
|
||||
service_id = request_msg['service_id']
|
||||
data_id = request_msg['data_id']
|
||||
if self.__prot__[prot_id].connection_established():
|
||||
logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
|
||||
self.__prot__[prot_id].send(service_id, data_id, None)
|
||||
else:
|
||||
wx.CallAfter(self.__no_data__, prot_id, service_id + 1, data_id)
|
||||
|
||||
def __task_1s_callback__(self, rt):
|
||||
# request data from fast prot ids
|
||||
self.__initiate_data_request__(rt, self.FAST_PROT_IDS)
|
||||
self.__initiate_data_request__(rt, self.REQUEST_MSGS_FAST)
|
||||
# set date and time
|
||||
wx.CallAfter(self.update_time)
|
||||
|
||||
def __task_10s_callback__(self, rt):
|
||||
# request data from slow prot ids
|
||||
self.__initiate_data_request__(rt, self.SLOW_PROT_IDS)
|
||||
self.__initiate_data_request__(rt, self.REQUEST_MSGS_SLOW)
|
||||
|
||||
def __task_60s_callback__(self, rt):
|
||||
# reconnect prots if needed
|
||||
for prot_id in self.ALL_PROT_IDS:
|
||||
if not self.__prot__[prot_id].is_connected():
|
||||
if not self.__prot__[prot_id].connected():
|
||||
logger.debug("Trying to reconnect prot_id %d", prot_id)
|
||||
self.__prot__[prot_id].reconnect()
|
||||
|
||||
def __initiate_data_request__(self, rt, prot_ids):
|
||||
for prot_id in prot_ids:
|
||||
if self.__prot__[prot_id].is_connected():
|
||||
for request_msg in self.REQUEST_MSGS.get(prot_id, []):
|
||||
service_id = request_msg['service_id']
|
||||
data_id = request_msg['data_id']
|
||||
logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
|
||||
self.__prot__[prot_id].send(service_id, data_id, None)
|
||||
else:
|
||||
logger.debug('Resetting GUI for prot_id %d', prot_id)
|
||||
wx.CallAfter(self.no_data[prot_id], None)
|
||||
def __validate_response_data__(self, prot_id, service_id, data_id, data):
|
||||
rv = False
|
||||
if prot_id == self.PROT_ID_GARAGE:
|
||||
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
||||
rv = isinstance(data, numbers.Number)
|
||||
elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
||||
if data is True:
|
||||
rv = True
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
rv = isinstance(data.get(dht_22.KEY_TEMPERATURE), numbers.Number) and isinstance(data.get(dht_22.KEY_HUMIDITY), numbers.Number) and isinstance(data.get(bmp_180.KEY_PRESSURE), numbers.Number)
|
||||
if rv is False:
|
||||
logger.warning("Validation failed for message: prot_id=%s, service_id=%s, data_id=%s, data=%s", repr(prot_id), repr(service_id), repr(data_id), repr(data))
|
||||
return rv
|
||||
|
||||
def __in_data__(self, msg):
|
||||
return self.__env_data__(msg, self.PROT_ID_IN)
|
||||
|
||||
def __out_data__(self, msg):
|
||||
return self.__env_data__(msg, self.PROT_ID_OUT)
|
||||
|
||||
def __env_data__(self, msg, prot_id):
|
||||
logger.debug('Received data for prot_id %d, service_id %d, data_id %d', prot_id, msg.get_service_id(), msg.get_data_id())
|
||||
if msg.get_status() == wetation_protocol.my_base_protocol_tcp.STATUS_OKAY:
|
||||
if msg.get_data_id() == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
wx.CallAfter(self.update_current_env_data_in, msg)
|
||||
else:
|
||||
wx.CallAfter(self.update_current_env_data_out, msg)
|
||||
def __prot_resp_callbacks__(self, msg, prot_id):
|
||||
service_id = msg.get_service_id()
|
||||
data_id = msg.get_data_id()
|
||||
data = msg.get_data()
|
||||
if self.__validate_response_data__(prot_id, service_id, data_id, data):
|
||||
wx.CallAfter(self.__data__, prot_id, service_id, data_id, data)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
else:
|
||||
logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
else:
|
||||
logger.error('Error, receiving environmental data! MSG_STATUS was %s with PROT_ID %d', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())), prot_id)
|
||||
wx.CallAfter(self.__no_data__, prot_id, service_id, data_id)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
||||
|
||||
def __garage_data__(self, msg):
|
||||
logger.debug('Received data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
||||
if msg.get_status() == garage_protocol.my_base_protocol_tcp.STATUS_OKAY:
|
||||
if msg.get_data_id() == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
||||
wx.CallAfter(self.update_gate_position, msg)
|
||||
def __no_data__(self, prot_id, service_id, data_id):
|
||||
if prot_id == self.PROT_ID_GARAGE:
|
||||
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
||||
logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
||||
self.heading_garage.Show(False)
|
||||
self.gate_oc.Show(False)
|
||||
self.gate_open.Show(False)
|
||||
self.gate_position.Show(False)
|
||||
self.gate_close.Show(False)
|
||||
self.Layout()
|
||||
return
|
||||
elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
||||
return
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
||||
txt_temperature = '-.- °C'
|
||||
txt_humidity = '-.- %'
|
||||
txt_pressure = '- hPa'
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
self.in_temperature.SetLabel(txt_temperature)
|
||||
self.in_humidity.SetLabel(txt_humidity)
|
||||
self.in_pressure.SetLabel(txt_pressure)
|
||||
else:
|
||||
self.out_temperature.SetLabel(txt_temperature)
|
||||
self.out_humidity.SetLabel(txt_humidity)
|
||||
self.out_pressure.SetLabel(txt_pressure)
|
||||
self.Layout()
|
||||
return
|
||||
logger.warning("Unknown response with no valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
||||
|
||||
def __data__(self, prot_id, service_id, data_id, data):
|
||||
if prot_id == self.PROT_ID_GARAGE:
|
||||
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
||||
self.heading_garage.Show(True)
|
||||
self.gate_oc.Show(True)
|
||||
self.gate_open.Show(True)
|
||||
self.gate_position.Show(True)
|
||||
self.gate_close.Show(True)
|
||||
self.gate_position.SetValue(int(data * 100))
|
||||
self.Layout()
|
||||
return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
||||
return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
temp = data[dht_22.KEY_TEMPERATURE]
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
if self.__max_temp_in__ is None or temp > self.__max_temp_in__:
|
||||
self.__max_temp_in__ = temp
|
||||
if self.__min_temp_in__ is None or temp < self.__min_temp_in__:
|
||||
self.__min_temp_in__ = temp
|
||||
wx.CallAfter(self.update_current_env_data, data, self.in_temperature, self.in_humidity, self.in_pressure, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
|
||||
else:
|
||||
logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
|
||||
else:
|
||||
logger.error('Error, receiving garage data! MSG_STATUS was %s', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())))
|
||||
return garage_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
||||
if self.__max_temp_out__ is None or temp > self.__max_temp_out__:
|
||||
self.__max_temp_out__ = temp
|
||||
if self.__min_temp_out__ is None or temp < self.__min_temp_out__:
|
||||
self.__min_temp_out__ = temp
|
||||
wx.CallAfter(self.update_current_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
logger.warning("Unknown response with valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
||||
|
||||
|
||||
def update_current_env_data_in(self, msg):
|
||||
if msg is None:
|
||||
temperature = '-.-'
|
||||
humidity = '-.-'
|
||||
pressure = '-'
|
||||
else:
|
||||
env_data = msg.get_data()
|
||||
temperature = '%.1f' % env_data[envsens.KEY_TEMPERATURE]
|
||||
humidity = '%.1f' % env_data[envsens.KEY_HUMIDITY]
|
||||
pressure = '%.0f' % env_data[envsens.KEY_PRESSURE]
|
||||
self.in_temperature.SetLabel("%s °C" % temperature)
|
||||
self.in_humidity.SetLabel("%s %%" % humidity)
|
||||
self.in_pressure.SetLabel("%s hPa" % pressure)
|
||||
self.Layout()
|
||||
|
||||
def update_current_env_data_out(self, msg):
|
||||
if msg is None:
|
||||
temperature = '-.-'
|
||||
humidity = '-.-'
|
||||
pressure = '-'
|
||||
else:
|
||||
env_data = msg.get_data()
|
||||
temperature = "%.1f" % env_data[envsens.KEY_TEMPERATURE]
|
||||
humidity = "%.1f" % env_data[envsens.KEY_HUMIDITY]
|
||||
pressure = "%.0f" % env_data[envsens.KEY_PRESSURE]
|
||||
self.out_temperature.SetLabel("%s °C" % temperature)
|
||||
self.out_humidity.SetLabel("%s %%" % humidity)
|
||||
self.out_pressure.SetLabel("%s hPa" % pressure)
|
||||
self.Layout()
|
||||
|
||||
def update_gate_position(self, msg):
|
||||
self.heading_garage.Show(msg is not None)
|
||||
self.gate_oc.Show(msg is not None)
|
||||
self.gate_open.Show(msg is not None)
|
||||
self.gate_position.Show(msg is not None)
|
||||
self.gate_close.Show(msg is not None)
|
||||
if msg is not None:
|
||||
self.gate_position.SetValue(msg.get_data() * 100)
|
||||
def update_current_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
|
||||
if isinstance(value_min, numbers.Number) and isinstance(value_max, numbers.Number):
|
||||
temperature_min.SetLabel('%.1f' % value_min)
|
||||
temperature_max.SetLabel('%.1f' % value_max)
|
||||
temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE])
|
||||
humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY])
|
||||
pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE])
|
||||
self.Layout()
|
||||
|
||||
def update_time(self):
|
||||
@ -210,11 +235,27 @@ class WetationFrameProt(gui.Wetation):
|
||||
self.date.SetLabel(time.strftime("%d.%m.%Y"))
|
||||
self.Layout()
|
||||
|
||||
def gate_oc_evt(self, event): # wxGlade: Wetation.<event_handler>
|
||||
def gate_oc_evt(self, event):
|
||||
logger.debug("Gate open/close request")
|
||||
self.__prot__[self.PROT_ID_GARAGE].send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
|
||||
event.Skip()
|
||||
|
||||
def reset_in_temp_minmax_evt(self, event):
|
||||
self.__min_temp_in__ = None
|
||||
self.__max_temp_in__ = None
|
||||
self.in_temperature_min.SetLabel("-.- °C")
|
||||
self.in_temperature_max.SetLabel("-.- °C")
|
||||
self.Layout()
|
||||
event.Skip()
|
||||
|
||||
def reset_out_temp_minmax_evt(self, event):
|
||||
self.__min_temp_out__ = None
|
||||
self.__max_temp_out__ = None
|
||||
self.out_temperature_min.SetLabel("-.- °C")
|
||||
self.out_temperature_max.SetLabel("-.- °C")
|
||||
self.Layout()
|
||||
event.Skip()
|
||||
|
||||
def run(self):
|
||||
self.__task_1s__.run()
|
||||
self.__task_10s__.run()
|
||||
|
@ -1 +1 @@
|
||||
Subproject commit f4a7f1e7a4156f397ee76bee01b0fdab88a727d1
|
||||
Subproject commit cd508340e390fc01ebdf81eae3b1e221aa1b658a
|
@ -1 +1 @@
|
||||
Subproject commit 3e6e74f976a1322d97f1d50480df133455486fd6
|
||||
Subproject commit d9bdc909e98f627fea4417d027ae5d9cb9e2ed81
|
@ -1 +1 @@
|
||||
Subproject commit 53e4523c140b5f51dedb3b128048eb59c1a5da4c
|
||||
Subproject commit bc4808b313ecebba6511b82c801eeadd95e8a503
|
Loading…
x
Reference in New Issue
Block a user