@@ -22,7 +22,6 @@ try:
|
22
|
22
|
from config import APP_NAME as ROOT_LOGGER_NAME
|
23
|
23
|
except ImportError:
|
24
|
24
|
ROOT_LOGGER_NAME = 'root'
|
25
|
|
-logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__)
|
26
|
25
|
|
27
|
26
|
|
28
|
27
|
class WetationFrameProt(gui.Wetation):
|
|
@@ -108,6 +107,7 @@ class WetationFrameProt(gui.Wetation):
|
108
|
107
|
self.ShowFullScreen(config.FULL_SCREEN)
|
109
|
108
|
|
110
|
109
|
self.__init_communication__()
|
|
110
|
+ time.sleep(3.5) # Wait for established connections before starting the tasks
|
111
|
111
|
|
112
|
112
|
self.__task_1s__ = task.periodic(1, self.__task_1s_callback__)
|
113
|
113
|
self.__task_10s__ = task.periodic(10, self.__task_10s_callback__)
|
|
@@ -117,19 +117,23 @@ class WetationFrameProt(gui.Wetation):
|
117
|
117
|
#
|
118
|
118
|
# Start TCP-Clients
|
119
|
119
|
for prot_id in self.ALL_PROT_IDS:
|
120
|
|
- logger.debug('Initiating communication channel for prot_id %d', prot_id)
|
|
120
|
+ cn = self.PROT_NAMES[prot_id]
|
|
121
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
|
122
|
+ logger.info('Initiating communication channel')
|
121
|
123
|
c_tcp = tcp_socket.tcp_client_stp(self.PROT_IPS[prot_id], self.PROT_PORTS[prot_id], rx_log_lvl=logging.DEBUG)
|
122
|
|
- self.__prot__[prot_id] = self.PROT_CLASSES[prot_id](c_tcp, secret=self.PROT_SECRETS[prot_id], auto_auth=True, channel_name=self.PROT_NAMES[prot_id])
|
|
124
|
+ self.__prot__[prot_id] = self.PROT_CLASSES[prot_id](c_tcp, secret=self.PROT_SECRETS[prot_id], auto_auth=True, channel_name=cn)
|
123
|
125
|
#
|
124
|
126
|
self.__prot__[prot_id].register_callback(None, None, self.__prot_resp_callbacks__, prot_id)
|
125
|
127
|
|
126
|
128
|
def __initiate_data_request__(self, rt, request_msgs):
|
127
|
129
|
for prot_id in request_msgs:
|
|
130
|
+ cn = self.PROT_NAMES[prot_id]
|
|
131
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
128
|
132
|
for request_msg in request_msgs.get(prot_id, []):
|
129
|
133
|
service_id = request_msg['service_id']
|
130
|
134
|
data_id = request_msg['data_id']
|
131
|
135
|
if self.__prot__[prot_id].connection_established():
|
132
|
|
- logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
|
|
136
|
+ logger.debug('Sending data request for service_id %d and data_id %d', service_id, data_id)
|
133
|
137
|
self.__prot__[prot_id].send(service_id, data_id, None)
|
134
|
138
|
else:
|
135
|
139
|
wx.CallAfter(self.__no_data__, prot_id, service_id + 1, data_id)
|
|
@@ -147,12 +151,16 @@ class WetationFrameProt(gui.Wetation):
|
147
|
151
|
def __task_60s_callback__(self, rt):
|
148
|
152
|
# reconnect prots if needed
|
149
|
153
|
for prot_id in self.ALL_PROT_IDS:
|
|
154
|
+ cn = self.PROT_NAMES[prot_id]
|
|
155
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
150
|
156
|
if not self.__prot__[prot_id].connected():
|
151
|
|
- logger.debug("Trying to reconnect prot_id %d", prot_id)
|
|
157
|
+ logger.warning("Trying to reconnect prot_id %d", prot_id)
|
152
|
158
|
self.__prot__[prot_id].reconnect()
|
153
|
159
|
|
154
|
160
|
def __validate_response_data__(self, prot_id, service_id, data_id, data):
|
155
|
161
|
rv = False
|
|
162
|
+ cn = self.PROT_NAMES[prot_id]
|
|
163
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
156
|
164
|
if prot_id == self.PROT_ID_GARAGE:
|
157
|
165
|
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
158
|
166
|
rv = isinstance(data, numbers.Number)
|
|
@@ -198,9 +206,11 @@ class WetationFrameProt(gui.Wetation):
|
198
|
206
|
return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
199
|
207
|
|
200
|
208
|
def __no_data__(self, prot_id, service_id, data_id):
|
|
209
|
+ cn = self.PROT_NAMES[prot_id]
|
|
210
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
201
|
211
|
if prot_id == self.PROT_ID_GARAGE:
|
202
|
212
|
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
203
|
|
- logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
|
213
|
+ logger.warning('Resetting GUI elements for %s', cn)
|
204
|
214
|
self.heading_garage.Show(False)
|
205
|
215
|
self.gate_oc.Show(False)
|
206
|
216
|
self.gate_open.Show(False)
|
|
@@ -212,7 +222,7 @@ class WetationFrameProt(gui.Wetation):
|
212
|
222
|
return
|
213
|
223
|
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
214
|
224
|
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
|
215
|
|
- logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
|
225
|
+ logger.warning('Resetting GUI elements for %s', cn)
|
216
|
226
|
txt_pressure = '- hPa'
|
217
|
227
|
if prot_id == self.PROT_ID_IN:
|
218
|
228
|
self.in_pressure.SetLabel(txt_pressure)
|
|
@@ -221,7 +231,7 @@ class WetationFrameProt(gui.Wetation):
|
221
|
231
|
self.Layout()
|
222
|
232
|
return
|
223
|
233
|
elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
|
224
|
|
- logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
|
234
|
+ logger.warning('Resetting GUI elements for %s', cn)
|
225
|
235
|
txt_temperature = '-.- °C'
|
226
|
236
|
txt_humidity = '-.- %'
|
227
|
237
|
if prot_id == self.PROT_ID_IN:
|
|
@@ -235,8 +245,11 @@ class WetationFrameProt(gui.Wetation):
|
235
|
245
|
logger.warning("Unknown response with no valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
236
|
246
|
|
237
|
247
|
def __data__(self, prot_id, service_id, data_id, data):
|
|
248
|
+ cn = self.PROT_NAMES[prot_id]
|
|
249
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
238
|
250
|
if prot_id == self.PROT_ID_GARAGE:
|
239
|
251
|
if service_id == garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
|
|
252
|
+ logger.debug('Setting %s position to %3d', cn, int(data * 100))
|
240
|
253
|
self.heading_garage.Show(True)
|
241
|
254
|
self.gate_oc.Show(True)
|
242
|
255
|
self.gate_open.Show(True)
|
|
@@ -250,6 +263,7 @@ class WetationFrameProt(gui.Wetation):
|
250
|
263
|
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
251
|
264
|
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
|
252
|
265
|
data = helpers.continues_statistic_multivalue(**data)
|
|
266
|
+ logger.debug('Setting %s pressure to %4d hPa', cn, data[bmp_180.KEY_PRESSURE].mean)
|
253
|
267
|
#
|
254
|
268
|
# Current environmental data
|
255
|
269
|
if prot_id == self.PROT_ID_IN:
|
|
@@ -262,6 +276,8 @@ class WetationFrameProt(gui.Wetation):
|
262
|
276
|
#
|
263
|
277
|
# Current environmental data
|
264
|
278
|
temp = data[dht_22.KEY_TEMPERATURE].mean
|
|
279
|
+ logger.debug('Setting %s temperature to %4.1f °C', cn, temp)
|
|
280
|
+ logger.debug('Setting %s humidity to %3.1f %%', cn, data[dht_22.KEY_HUMIDITY].mean)
|
265
|
281
|
if prot_id == self.PROT_ID_IN:
|
266
|
282
|
if self.__max_temp_in__ is None or temp > self.__max_temp_in__:
|
267
|
283
|
self.__max_temp_in__ = temp
|
|
@@ -295,6 +311,8 @@ class WetationFrameProt(gui.Wetation):
|
295
|
311
|
self.Layout()
|
296
|
312
|
|
297
|
313
|
def gate_oc_evt(self, event):
|
|
314
|
+ cn = self.PROT_NAMES[self.PROT_ID_GARAGE]
|
|
315
|
+ logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__ + '.' + cn)
|
298
|
316
|
r = wx.MessageDialog(
|
299
|
317
|
self,
|
300
|
318
|
"Soll das Garagentor betätigt werden?",
|