123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226 |
- #!/usr/bin/env python
- # -*- coding: UTF-8 -*-
- #
-
- #TODO: Zyklischer reconnect versuch (ggf. inkl. herstellen der Schnittstelle für ein reconnect beim tcp_client)
-
- import config
- import rpi_envsens as envsens
- import garage_protocol
- import gui
- import logging
- import os
- import report
- import task
- import tcp_socket
- import time
- import wetation_protocol
- import wx
-
- logger = logging.getLogger('APP')
-
-
- class WetationFrameProt(gui.Wetation):
- PROT_ID_GARAGE = 0
- PROT_ID_IN = 1
- PROT_ID_OUT = 2
- ALL_PROT_IDS = [PROT_ID_GARAGE, PROT_ID_IN, PROT_ID_OUT]
-
- REQUEST_MSGS = {
- PROT_ID_GARAGE: [
- {
- 'service_id': garage_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
- 'data_id': garage_protocol.my_base_protocol_tcp.GATE_POSITION,
- },
- ],
- PROT_ID_IN: [
- {
- 'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
- 'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
- },
- ],
- PROT_ID_OUT: [
- {
- 'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
- 'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
- },
- ],
- }
-
-
- def __init__(self, *args, **kwds):
- self.__prot__ = {}
- self.no_data = {
- self.PROT_ID_GARAGE: self.update_gate_position,
- self.PROT_ID_IN: self.update_current_env_data_in,
- self.PROT_ID_OUT: self.update_current_env_data_out,
- }
- gui.Wetation.__init__(self, *args, **kwds)
- self.ShowFullScreen(config.FULL_SCREEN)
-
- self.__init_communication__()
- self.__task_data_request__ = task.periodic(10, self.__initiate_data_request__)
-
- def __init_protocol__(self, prot_id, ip, port, prot_class, secret):
- c_tcp = tcp_socket.tcp_client_stp(ip, port, rx_log_lvl=logging.DEBUG)
- self.__prot__[prot_id] = prot_class(c_tcp, secret)
- if config.server_garage_secret is not None:
- self.__prot__[prot_id].authentificate()
-
- def __init_communication__(self):
- #
- # Start TCP-Clients
- self.__init_protocol__(
- self.PROT_ID_GARAGE,
- config.server_garage_ip,
- config.server_garage_port,
- garage_protocol.my_base_protocol_tcp,
- config.server_garage_secret
- )
- self.__prot__[self.PROT_ID_GARAGE].register_callback(garage_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__garage_data__)
-
- self.__init_protocol__(
- self.PROT_ID_IN,
- config.server_in_ip,
- config.server_in_port,
- wetation_protocol.my_base_protocol_tcp,
- config.server_in_secret
- )
- self.__prot__[self.PROT_ID_IN].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__in_data__)
-
- self.__init_protocol__(
- self.PROT_ID_OUT,
- config.server_out_ip,
- config.server_out_port,
- wetation_protocol.my_base_protocol_tcp,
- config.server_out_secret
- )
- self.__prot__[self.PROT_ID_OUT].register_callback(wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE, None, self.__out_data__)
-
- def __initiate_data_request__(self, rt):
- for prot_id in self.ALL_PROT_IDS:
- if self.__prot__[prot_id].is_connected():
- for request_msg in self.REQUEST_MSGS.get(prot_id, []):
- service_id = request_msg['service_id']
- data_id = request_msg['data_id']
- logger.debug('Sending data request for prot_id %d, service_id %d and data_id %d', prot_id, service_id, data_id)
- self.__prot__[prot_id].send(service_id, data_id, None)
- else:
- logger.debug('Resetting GUI for prot_id %d', prot_id)
- wx.CallAfter(self.no_data[prot_id], None)
-
- # TODO: Move the following three lines to the wx idle task
- wx.CallAfter(self.update_time)
-
- def __in_data__(self, msg):
- return self.__env_data__(msg, self.PROT_ID_IN)
-
- def __out_data__(self, msg):
- return self.__env_data__(msg, self.PROT_ID_OUT)
-
- def __env_data__(self, msg, prot_id):
- logger.debug('Received data for prot_id %d, service_id %d, data_id %d', prot_id, msg.get_service_id(), msg.get_data_id())
- if msg.get_status() == wetation_protocol.my_base_protocol_tcp.STATUS_OKAY:
- if msg.get_data_id() == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
- if prot_id == self.PROT_ID_IN:
- wx.CallAfter(self.update_current_env_data_in, msg)
- else:
- wx.CallAfter(self.update_current_env_data_out, msg)
- return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
- else:
- logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
- return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
- else:
- logger.error('Error, receiving environmental data! MSG_STATUS was %s with PROT_ID %d', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())), prot_id)
- return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
-
- def __garage_data__(self, msg):
- logger.debug('Received data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
- if msg.get_status() == garage_protocol.my_base_protocol_tcp.STATUS_OKAY:
- if msg.get_data_id() == garage_protocol.my_base_protocol_tcp.GATE_POSITION:
- wx.CallAfter(self.update_gate_position, msg)
- return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
- else:
- logger.warning('Received unknown data for prot_id %d, service_id %d, data_id %d', self.PROT_ID_GARAGE, msg.get_service_id(), msg.get_data_id())
- else:
- logger.error('Error, receiving garage data! MSG_STATUS was %s', garage_protocol.my_base_protocol_tcp.STATUS_NAMES.get(msg.get_status(), repr(msg.get_status())))
- return garage_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
-
-
- def update_current_env_data_in(self, msg):
- if msg is None:
- temperature = '-.-'
- humidity = '-.-'
- pressure = '-'
- else:
- env_data = msg.get_data()
- temperature = '%.1f' % env_data[envsens.KEY_TEMPERATURE]
- humidity = '%.1f' % env_data[envsens.KEY_HUMIDITY]
- pressure = '%.0f' % env_data[envsens.KEY_PRESSURE]
- self.in_temperature.SetLabel("%s °C" % temperature)
- self.in_humidity.SetLabel("%s %%" % humidity)
- self.in_pressure.SetLabel("%s hPa" % pressure)
- self.Layout()
-
- def update_current_env_data_out(self, msg):
- if msg is None:
- temperature = '-.-'
- humidity = '-.-'
- pressure = '-'
- else:
- env_data = msg.get_data()
- temperature = "%.1f" % env_data[envsens.KEY_TEMPERATURE]
- humidity = "%.1f" % env_data[envsens.KEY_HUMIDITY]
- pressure = "%.0f" % env_data[envsens.KEY_PRESSURE]
- self.out_temperature.SetLabel("%s °C" % temperature)
- self.out_humidity.SetLabel("%s %%" % humidity)
- self.out_pressure.SetLabel("%s hPa" % pressure)
- self.Layout()
-
- def update_gate_position(self, msg):
- self.heading_garage.Show(msg is not None)
- self.gate_oc.Show(msg is not None)
- self.gate_open.Show(msg is not None)
- self.gate_position.Show(msg is not None)
- self.gate_close.Show(msg is not None)
- if msg is not None:
- self.gate_position.SetValue(msg.get_data() * 100)
- self.Layout()
-
- def update_time(self):
- self.time.SetLabel(time.strftime("%H:%M"))
- self.date.SetLabel(time.strftime("%d.%m.%Y"))
- self.Layout()
-
- def gate_oc_evt(self, event): # wxGlade: Wetation.<event_handler>
- self.prot_garage.send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
- event.Skip()
-
- def run(self):
- self.__task_data_request__.run()
-
- def close(self):
- self.__task_data_request__.stop()
- self.__task_data_request__.join()
-
- def __del__(self):
- self.close()
-
-
- class MyApp(wx.App):
- def OnInit(self):
- self.frame = WetationFrameProt(None, wx.ID_ANY, "")
- self.SetTopWindow(self.frame)
- self.frame.Show()
- return True
-
-
-
-
- if __name__ == "__main__":
- report.appLoggingConfigure(os.path.dirname(__file__), config.LOGTARGET, config.loggers)
- #
- app = MyApp(0)
- app.frame.run()
- app.MainLoop()
- app.frame.close()
|