import time
|
|
|
|
from . import logger, background_task
|
|
try:
|
|
import smbus
|
|
except ImportError:
|
|
logger.warning("Could not import smbus. DEBUG set to True.")
|
|
DEBUG = True
|
|
else:
|
|
from . import DEBUG
|
|
|
|
|
|
class bmp_180(background_task):
|
|
RUN_SLEEP_TIME = 0.5
|
|
SMBUS_DELAY = 0.5
|
|
MIN_REFRESH_RATE = RUN_SLEEP_TIME + 3 * SMBUS_DELAY
|
|
KEY_TEMPERATURE = 'temperature'
|
|
KEY_PRESSURE = 'pressure'
|
|
KEY_TIME = 'time'
|
|
|
|
def __init__(self, data_callback=None):
|
|
self.__data_callback__ = data_callback
|
|
# Initialise background_task
|
|
background_task.__init__(self)
|
|
|
|
def __run__(self):
|
|
data = self.__bmp_data_transmission__()
|
|
if data is not None:
|
|
logger.debug('BMP-Communication: Successfully: %s', repr(data))
|
|
if self.__data_callback__ is not None:
|
|
self.__data_callback__(**data)
|
|
|
|
def __bmp_data_transmission__(self):
|
|
if not DEBUG:
|
|
rv = {}
|
|
# Get I2C bus
|
|
bus = smbus.SMBus(1)
|
|
|
|
# BMP180 address, 0x77(119)
|
|
# Read data back from 0xAA(170), 22 bytes
|
|
data = bus.read_i2c_block_data(0x77, 0xAA, 22)
|
|
|
|
# Convert the data
|
|
AC1 = data[0] * 256 + data[1]
|
|
if AC1 > 32767 :
|
|
AC1 -= 65535
|
|
AC2 = data[2] * 256 + data[3]
|
|
if AC2 > 32767 :
|
|
AC2 -= 65535
|
|
AC3 = data[4] * 256 + data[5]
|
|
if AC3 > 32767 :
|
|
AC3 -= 65535
|
|
AC4 = data[6] * 256 + data[7]
|
|
AC5 = data[8] * 256 + data[9]
|
|
AC6 = data[10] * 256 + data[11]
|
|
B1 = data[12] * 256 + data[13]
|
|
if B1 > 32767 :
|
|
B1 -= 65535
|
|
B2 = data[14] * 256 + data[15]
|
|
if B2 > 32767 :
|
|
B2 -= 65535
|
|
MB = data[16] * 256 + data[17]
|
|
if MB > 32767 :
|
|
MB -= 65535
|
|
MC = data[18] * 256 + data[19]
|
|
if MC > 32767 :
|
|
MC -= 65535
|
|
MD = data[20] * 256 + data[21]
|
|
if MD > 32767 :
|
|
MD -= 65535
|
|
|
|
time.sleep(self.SMBUS_DELAY)
|
|
|
|
# BMP180 address, 0x77(119)
|
|
# Select measurement control register, 0xF4(244)
|
|
# 0x2E(46) Enable temperature measurement
|
|
bus.write_byte_data(0x77, 0xF4, 0x2E)
|
|
|
|
time.sleep(self.SMBUS_DELAY)
|
|
|
|
# BMP180 address, 0x77(119)
|
|
# Read data back from 0xF6(246), 2 bytes
|
|
# temp MSB, temp LSB
|
|
data = bus.read_i2c_block_data(0x77, 0xF6, 2)
|
|
|
|
# Convert the data
|
|
temp = data[0] * 256 + data[1]
|
|
|
|
# BMP180 address, 0x77(119)
|
|
# Select measurement control register, 0xF4(244)
|
|
# 0x74(116) Enable pressure measurement, OSS = 1
|
|
bus.write_byte_data(0x77, 0xF4, 0x74)
|
|
|
|
time.sleep(self.SMBUS_DELAY)
|
|
|
|
# BMP180 address, 0x77(119)
|
|
# Read data back from 0xF6(246), 3 bytes
|
|
# pres MSB1, pres MSB, pres LSB
|
|
data = bus.read_i2c_block_data(0x77, 0xF6, 3)
|
|
|
|
rv[self.KEY_TIME] = int(time.time())
|
|
|
|
# Convert the data
|
|
pres = ((data[0] * 65536) + (data[1] * 256) + data[2]) / 128
|
|
# Callibration for Temperature
|
|
X1 = (temp - AC6) * AC5 / 32768.0
|
|
X2 = (MC * 2048.0) / (X1 + MD)
|
|
B5 = X1 + X2
|
|
rv[self.KEY_TEMPERATURE] = ((B5 + 8.0) / 16.0) / 10.0
|
|
|
|
# Calibration for Pressure
|
|
B6 = B5 - 4000
|
|
X1 = (B2 * (B6 * B6 / 4096.0)) / 2048.0
|
|
X2 = AC2 * B6 / 2048.0
|
|
X3 = X1 + X2
|
|
B3 = (((AC1 * 4 + X3) * 2) + 2) / 4.0
|
|
X1 = AC3 * B6 / 8192.0
|
|
X2 = (B1 * (B6 * B6 / 2048.0)) / 65536.0
|
|
X3 = ((X1 + X2) + 2) / 4.0
|
|
B4 = AC4 * (X3 + 32768) / 32768.0
|
|
B7 = ((pres - B3) * (25000.0))
|
|
pressure = 0.0
|
|
if B7 < 2147483648:
|
|
pressure = (B7 * 2) / B4
|
|
else :
|
|
pressure = (B7 / B4) * 2
|
|
X1 = (pressure / 256.0) * (pressure / 256.0)
|
|
X1 = (X1 * 3038.0) / 65536.0
|
|
X2 = ((-7357) * pressure) / 65536.0
|
|
rv[self.KEY_PRESSURE] = (pressure + (X1 + X2 + 3791) / 16.0) / 100
|
|
|
|
return rv
|
|
else:
|
|
time.sleep(3 * self.SMBUS_DELAY)
|
|
return {
|
|
self.KEY_PRESSURE: 1717.,
|
|
self.KEY_TEMPERATURE: 17.17,
|
|
self.KEY_TIME: int(time.time())
|
|
}
|