@@ -17,6 +17,7 @@ import devices
|
17
|
17
|
from function.helpers import day_state
|
18
|
18
|
import logging
|
19
|
19
|
import task
|
|
20
|
+import time
|
20
|
21
|
|
21
|
22
|
try:
|
22
|
23
|
from config import APP_NAME as ROOT_LOGGER_NAME
|
|
@@ -152,10 +153,35 @@ class heating_function(common_base):
|
152
|
153
|
AWAY_REDUCTION = 5
|
153
|
154
|
SUMMER_TEMPERATURE = 5
|
154
|
155
|
|
|
156
|
+ class value_timeout_list(object):
|
|
157
|
+ MAX_DELAY = 3
|
|
158
|
+
|
|
159
|
+ def __init__(self):
|
|
160
|
+ self.__data__ = []
|
|
161
|
+ self.__time__ = []
|
|
162
|
+
|
|
163
|
+ def __cleanup__(self):
|
|
164
|
+ now = time.time()
|
|
165
|
+ for i, tm in enumerate(self.__time__):
|
|
166
|
+ if tm + self.MAX_DELAY < now:
|
|
167
|
+ del (self.__data__[i])
|
|
168
|
+ del (self.__time__[i])
|
|
169
|
+
|
|
170
|
+ def new(self, item):
|
|
171
|
+ self.__cleanup__()
|
|
172
|
+ self.__data__.append(item)
|
|
173
|
+ self.__time__.append(time.time())
|
|
174
|
+
|
|
175
|
+ def is_valid_value(self, data):
|
|
176
|
+ self.__cleanup__()
|
|
177
|
+ return data not in self.__data__
|
|
178
|
+
|
155
|
179
|
def __init__(self, heating_valve, default_temperature, **kwargs):
|
156
|
180
|
self.heating_valve = heating_valve
|
157
|
181
|
self.default_temperature = default_temperature
|
158
|
182
|
#
|
|
183
|
+ self.valve_value = self.value_timeout_list()
|
|
184
|
+ #
|
159
|
185
|
super().__init__({
|
160
|
186
|
self.KEY_USER_TEMPERATURE_SETPOINT: kwargs.get(self.KEY_USER_TEMPERATURE_SETPOINT, self.default_temperature),
|
161
|
187
|
self.KEY_TEMPERATURE_SETPOINT: kwargs.get(self.KEY_TEMPERATURE_SETPOINT, self.default_temperature),
|
|
@@ -241,11 +267,13 @@ class heating_function(common_base):
|
241
|
267
|
self.set(self.KEY_TEMPERATURE_SETPOINT, data)
|
242
|
268
|
|
243
|
269
|
def set_heating_setpoint(self, device, key, data):
|
|
270
|
+ self.valve_value.new(data)
|
244
|
271
|
self.heating_valve.set_heating_setpoint(data)
|
245
|
272
|
|
246
|
273
|
def get_radiator_setpoint(self, device, key, data):
|
247
|
|
- if self[self.KEY_BOOST_TIMER] == 0 and not self[self.KEY_AWAY_MODE] and not self[self.KEY_SUMMER_MODE]:
|
248
|
|
- self.set(self.KEY_USER_TEMPERATURE_SETPOINT, data, block_callback=[self.set_heating_setpoint])
|
|
274
|
+ if self.valve_value.is_valid_value(data):
|
|
275
|
+ if self[self.KEY_BOOST_TIMER] == 0 and not self[self.KEY_AWAY_MODE] and not self[self.KEY_SUMMER_MODE]:
|
|
276
|
+ self.set(self.KEY_USER_TEMPERATURE_SETPOINT, data, block_callback=[self.set_heating_setpoint])
|
249
|
277
|
|
250
|
278
|
def get_radiator_temperature(self, device, key, data):
|
251
|
279
|