#!/usr/bin/env python # -*- coding: utf-8 -*- # import devices import logging import task try: from config import APP_NAME as ROOT_LOGGER_NAME except ImportError: ROOT_LOGGER_NAME = 'root' logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__) class heating_function_brennenstuhl(object): RETURN_TO_DEFAULT_TIME = 45 * 60 BOOST_TEMP_OFFSET = 5 def __init__(self, mqtt_client, topic_valve, default_temperature, topic_boost, topic_setpoint, topic_led): self.ct = task.periodic(1, self.cyclic_task) # self.topic = topic_valve self.default_temperature = default_temperature # self.heating_valve = devices.brennenstuhl_heatingvalve(mqtt_client, topic_valve) self.heating_valve.set_heating_setpoint(self.default_temperature) self.heating_valve.add_callback( devices.brennenstuhl_heatingvalve.KEY_HEATING_SETPOINT, None, self.heating_setpoint_actions) self.gui_value_temp_setp = devices.nodered_gui_heatvalve(mqtt_client, topic_setpoint) self.gui_value_temp_setp.add_callback( devices.nodered_gui_heatvalve.KEY_HEATING_SETPOINT, None, self.heating_setpoint_actions) self.gui_button_boost = devices.nodered_gui_heatvalve(mqtt_client, topic_boost) self.gui_button_boost.add_callback(None, None, self.boost_actions) self.gui_led_boost = devices.nodered_gui_heatvalve(mqtt_client, topic_led) # self.return_to_default_timer = None self.return_to_default_setpoint = None self.gui_led_boost.set_feedback(False) # self.ct.run() def heating_setpoint_actions(self, device, key, data): if device.topic == self.heating_valve.topic: # valve setpoint action self.gui_value_temp_setp.set_feedback(data) if data > self.default_temperature: if data != self.return_to_default_setpoint: logger.info('Got heating setpoint (%.1f°C) \"%s\" with deviation to the default value (%.1f°C). Starting timer for returning to default.', data, self.topic, self.default_temperature) self.return_to_default_timer = self.RETURN_TO_DEFAULT_TIME self.return_to_default_setpoint = data self.gui_led_boost.set_feedback(True) else: if self.return_to_default_timer is not None: logger.info('Deleting timer \"%s\" for returning to default.', self.topic) self.return_to_default_timer = None self.return_to_default_setpoint = None self.gui_led_boost.set_feedback(False) elif device.topic == self.gui_value_temp_setp.topic: # user setpoint action logger.info('Setpoint change \"%s\" to %.1f°C', self.topic, data) self.default_temperature = data self.heating_valve.set_heating_setpoint(self.default_temperature) self.return_to_default_timer = None self.return_to_default_setpoint = None self.gui_led_boost.set_feedback(False) def boost_actions(self, davice, key, data): logger.info('Starting boost mode \"%s\" with setpoint %.1f°C.', self.topic, self.default_temperature + self.BOOST_TEMP_OFFSET) self.heating_valve.set_heating_setpoint(self.default_temperature + self.BOOST_TEMP_OFFSET) def cyclic_task(self, rt): if self.return_to_default_timer is not None: self.return_to_default_timer -= self.ct.cycle_time if self.return_to_default_timer <= 0: logger.info('Return to default timer expired \"%s\".', self.topic) self.heating_valve.set_heating_setpoint(self.default_temperature) self.return_to_default_timer = None self.return_to_default_setpoint = None self.gui_led_boost.set_feedback(False)