smart_brain/function/common.py

60 lines
2.0 KiB
Python

#!/usr/bin/env python
# -*- coding: utf-8 -*-
#
import devices
from function.rooms import room_shelly
from function.modules import heating_function_brennenstuhl
import logging
import task
try:
from config import APP_NAME as ROOT_LOGGER_NAME
except ImportError:
ROOT_LOGGER_NAME = 'root'
logger = logging.getLogger(ROOT_LOGGER_NAME).getChild(__name__)
class common_circulation_pump(room_shelly):
def __init__(self, mqtt_client):
# http://shelly1-E89F6D85A466
super().__init__(mqtt_client, "shellies/circulation_pump", "gui/common_sw_circulation_pump")
#
self.main_light_shelly.add_callback(devices.shelly.KEY_OUTPUT_0, None, self.circ_pump_actions)
#
self.gui_timer_view = devices.nodered_gui(mqtt_client, "gui/ffe_circ_pump_timer")
self.gui_timer_view.set_feedback('-')
#
self.last_pump_value = None
self.ct = task.periodic(6, self.cyclic_task)
self.pump_timer = None
#
self.ct.run()
def circ_pump_actions(self, device, key, data):
if self.last_pump_value != data and data is True:
self.pump_timer = 10
self.gui_timer_view.set_feedback(self.pump_timer)
elif data is False:
self.pump_timer = None
self.gui_timer_view.set_feedback('-')
self.last_pump_value = data
def cyclic_task(self, rt):
if self.pump_timer is not None:
if self.pump_timer <= 0:
self.pump_timer = None
self.gui_timer_view.set_feedback('-')
else:
self.gui_timer_view.set_feedback(self.pump_timer)
self.pump_timer -= self.ct.cycle_time / 60
class common_heating(object):
def __init__(self, mqtt_client):
self.ffe_heating_sleep_madi = heating_function_brennenstuhl(
mqtt_client, "zigbee_og_e/radiator/sleep_madi", 20, "gui/ffe_bo_sleep_madi", "gui/ffe_ts_sleep_madi", "gui/ffe_bl_sleep_madi")
def all_off(self):
pass # dummy method for compatibility reasons