Bladeren bron

wetation_server datatype changed to continues_statistic

mod_update
Dirk Alders 4 jaren geleden
bovenliggende
commit
704dcb758a
4 gewijzigde bestanden met toevoegingen van 82 en 26 verwijderingen
  1. 1
    1
      helpers
  2. 1
    1
      rpi_envsens
  3. 79
    23
      smarthome.py
  4. 1
    1
      wetation_protocol

+ 1
- 1
helpers

@@ -1 +1 @@
1
-Subproject commit 1819df790c0784473480dffe9aca8ca774d46343
1
+Subproject commit 43e0d556d1bbe6fed06bf5a90fa1bea8a8b2c81e

+ 1
- 1
rpi_envsens

@@ -1 +1 @@
1
-Subproject commit 5ffef8254a0a035bc11ccefbd19497dd3969ac10
1
+Subproject commit a0bfadcce811fcf2190d830dddb717dabc07875e

+ 79
- 23
smarthome.py Bestand weergeven

@@ -5,6 +5,7 @@
5 5
 import config
6 6
 from rpi_envsens.dht import dht_22
7 7
 from rpi_envsens.bmp import bmp_180
8
+import helpers
8 9
 import garage_protocol
9 10
 import gui
10 11
 import logging
@@ -54,13 +55,21 @@ class WetationFrameProt(gui.Wetation):
54 55
         PROT_ID_IN: [
55 56
             {
56 57
                 'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
57
-                'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
58
+                'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT,
59
+            },
60
+            {
61
+                'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
62
+                'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP,
58 63
             },
59 64
         ],
60 65
         PROT_ID_OUT: [
61 66
             {
62 67
                 'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
63
-                'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
68
+                'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT,
69
+            },
70
+            {
71
+                'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
72
+                'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP,
64 73
             },
65 74
         ],
66 75
     }
@@ -141,8 +150,28 @@ class WetationFrameProt(gui.Wetation):
141 150
                 if data is True:
142 151
                     rv = True
143 152
         elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
144
-            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
145
-                rv = isinstance(data.get(dht_22.KEY_TEMPERATURE), numbers.Number) and isinstance(data.get(dht_22.KEY_HUMIDITY), numbers.Number) and isinstance(data.get(bmp_180.KEY_PRESSURE), numbers.Number)
153
+            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
154
+                rv = True
155
+                for main_key in [bmp_180.KEY_PRESSURE, bmp_180.KEY_TEMPERATURE, bmp_180.KEY_TIME]:
156
+                    if main_key not in data:
157
+                        rv = False
158
+                        break
159
+                    else:
160
+                        for sub_key in ['mean', 'min_val', 'max_val', 'quantifier']:
161
+                            if not isinstance(data[main_key].get(sub_key), numbers.Number):
162
+                                rv = False
163
+                                break
164
+            elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
165
+                rv = True
166
+                for main_key in [dht_22.KEY_HUMIDITY, dht_22.KEY_TEMPERATURE, dht_22.KEY_TIME]:
167
+                    if main_key not in data:
168
+                        rv = False
169
+                        break
170
+                    else:
171
+                        for sub_key in ['mean', 'min_val', 'max_val', 'quantifier']:
172
+                            if not isinstance(data[main_key].get(sub_key), numbers.Number):
173
+                                rv = False
174
+                                break
146 175
         if rv is False:
147 176
             logger.warning("Validation failed for message: prot_id=%s, service_id=%s, data_id=%s, data=%s", repr(prot_id), repr(service_id), repr(data_id), repr(data))
148 177
         return rv
@@ -172,19 +201,25 @@ class WetationFrameProt(gui.Wetation):
172 201
             elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
173 202
                 return
174 203
         elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
175
-            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
204
+            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
205
+                logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
206
+                txt_pressure = '- hPa'
207
+                if prot_id == self.PROT_ID_IN:
208
+                    self.in_pressure.SetLabel(txt_pressure)
209
+                else:
210
+                    self.out_pressure.SetLabel(txt_pressure)
211
+                self.Layout()
212
+                return
213
+            elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
176 214
                 logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
177 215
                 txt_temperature = '-.- °C'
178 216
                 txt_humidity = '-.- %'
179
-                txt_pressure = '- hPa'
180 217
                 if prot_id == self.PROT_ID_IN:
181 218
                     self.in_temperature.SetLabel(txt_temperature)
182 219
                     self.in_humidity.SetLabel(txt_humidity)
183
-                    self.in_pressure.SetLabel(txt_pressure)
184 220
                 else:
185 221
                     self.out_temperature.SetLabel(txt_temperature)
186 222
                     self.out_humidity.SetLabel(txt_humidity)
187
-                    self.out_pressure.SetLabel(txt_pressure)
188 223
                 self.Layout()
189 224
                 return
190 225
         logger.warning("Unknown response with no valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
@@ -199,35 +234,49 @@ class WetationFrameProt(gui.Wetation):
199 234
                 self.gate_close.Show(True)
200 235
                 self.gate_position.SetValue(int(data * 100))
201 236
                 self.Layout()
202
-                return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
237
+                return
203 238
             elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
204
-                return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
239
+                return
205 240
         elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
206
-            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
207
-                temp = data[dht_22.KEY_TEMPERATURE]
241
+            if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
242
+                data = helpers.continues_statistic_multivalue(**data)
243
+                #
244
+                # Current environmental data
245
+                if prot_id == self.PROT_ID_IN:
246
+                    wx.CallAfter(self.update_current_bmp_env_data, data, self.in_pressure)
247
+                else:
248
+                    wx.CallAfter(self.update_current_bmp_env_data, data, self.out_pressure)
249
+                return
250
+            elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
251
+                data = helpers.continues_statistic_multivalue(**data)
252
+                #
253
+                # Current environmental data
254
+                temp = data[dht_22.KEY_TEMPERATURE].mean
208 255
                 if prot_id == self.PROT_ID_IN:
209 256
                     if self.__max_temp_in__ is None or temp > self.__max_temp_in__:
210 257
                         self.__max_temp_in__ = temp
211 258
                     if self.__min_temp_in__ is None or temp < self.__min_temp_in__:
212 259
                         self.__min_temp_in__ = temp
213
-                    wx.CallAfter(self.update_current_env_data, data, self.in_temperature, self.in_humidity, self.in_pressure, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
260
+                    wx.CallAfter(self.update_current_dht_env_data, data, self.in_temperature, self.in_humidity, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
214 261
                 else:
215 262
                     if self.__max_temp_out__ is None or temp > self.__max_temp_out__:
216 263
                         self.__max_temp_out__ = temp
217 264
                     if self.__min_temp_out__ is None or temp < self.__min_temp_out__:
218 265
                         self.__min_temp_out__ = temp
219
-                    wx.CallAfter(self.update_current_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
220
-                return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
266
+                    wx.CallAfter(self.update_current_dht_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
267
+                return
221 268
         logger.warning("Unknown response with valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
222
-        return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
223 269
 
224
-    def update_current_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
270
+    def update_current_bmp_env_data(self, env_data, pressure):
271
+        pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE].mean)
272
+        self.Layout()
273
+
274
+    def update_current_dht_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
225 275
         if isinstance(value_min, numbers.Number) and isinstance(value_max, numbers.Number):
226 276
             temperature_min.SetLabel('%.1f' % value_min)
227 277
             temperature_max.SetLabel('%.1f' % value_max)
228
-        temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE])
229
-        humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY])
230
-        pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE])
278
+        temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE].mean)
279
+        humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY].mean)
231 280
         self.Layout()
232 281
 
233 282
     def update_time(self):
@@ -236,8 +285,15 @@ class WetationFrameProt(gui.Wetation):
236 285
         self.Layout()
237 286
 
238 287
     def gate_oc_evt(self, event):
239
-        logger.debug("Gate open/close request")
240
-        self.__prot__[self.PROT_ID_GARAGE].send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
288
+        r = wx.MessageDialog(
289
+            self,
290
+            "Soll das Garagentor betätigt werden?",
291
+            "Garage",
292
+            wx.YES_NO | wx.NO_DEFAULT | wx.ICON_WARNING
293
+        ).ShowModal()
294
+        if r == wx.ID_YES:
295
+            logger.debug("Gate open/close request")
296
+            self.__prot__[self.PROT_ID_GARAGE].send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
241 297
         event.Skip()
242 298
 
243 299
     def reset_in_temp_minmax_evt(self, event):
@@ -284,7 +340,7 @@ class MyApp(wx.App):
284 340
 
285 341
 
286 342
 if __name__ == "__main__":
287
-    report.appLoggingConfigure(os.path.dirname(__file__), config.LOGTARGET, config.loggers)
343
+    report.appLoggingConfigure(os.path.dirname(__file__), config.LOGTARGET, config.loggers, fmt=config.formatter)
288 344
     #
289 345
     app = MyApp(0)
290 346
     app.frame.run()

+ 1
- 1
wetation_protocol

@@ -1 +1 @@
1
-Subproject commit bc4808b313ecebba6511b82c801eeadd95e8a503
1
+Subproject commit e9c6321772df731317b5398b624e10ff509d489b

Laden…
Annuleren
Opslaan