wetation_server datatype changed to continues_statistic
This commit is contained in:
parent
0bb85004d0
commit
704dcb758a
2
helpers
2
helpers
@ -1 +1 @@
|
||||
Subproject commit 1819df790c0784473480dffe9aca8ca774d46343
|
||||
Subproject commit 43e0d556d1bbe6fed06bf5a90fa1bea8a8b2c81e
|
@ -1 +1 @@
|
||||
Subproject commit 5ffef8254a0a035bc11ccefbd19497dd3969ac10
|
||||
Subproject commit a0bfadcce811fcf2190d830dddb717dabc07875e
|
98
smarthome.py
98
smarthome.py
@ -5,6 +5,7 @@
|
||||
import config
|
||||
from rpi_envsens.dht import dht_22
|
||||
from rpi_envsens.bmp import bmp_180
|
||||
import helpers
|
||||
import garage_protocol
|
||||
import gui
|
||||
import logging
|
||||
@ -54,13 +55,21 @@ class WetationFrameProt(gui.Wetation):
|
||||
PROT_ID_IN: [
|
||||
{
|
||||
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT,
|
||||
},
|
||||
{
|
||||
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP,
|
||||
},
|
||||
],
|
||||
PROT_ID_OUT: [
|
||||
{
|
||||
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT,
|
||||
},
|
||||
{
|
||||
'service_id': wetation_protocol.my_base_protocol_tcp.SID_READ_REQUEST,
|
||||
'data_id': wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP,
|
||||
},
|
||||
],
|
||||
}
|
||||
@ -141,8 +150,28 @@ class WetationFrameProt(gui.Wetation):
|
||||
if data is True:
|
||||
rv = True
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
rv = isinstance(data.get(dht_22.KEY_TEMPERATURE), numbers.Number) and isinstance(data.get(dht_22.KEY_HUMIDITY), numbers.Number) and isinstance(data.get(bmp_180.KEY_PRESSURE), numbers.Number)
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
|
||||
rv = True
|
||||
for main_key in [bmp_180.KEY_PRESSURE, bmp_180.KEY_TEMPERATURE, bmp_180.KEY_TIME]:
|
||||
if main_key not in data:
|
||||
rv = False
|
||||
break
|
||||
else:
|
||||
for sub_key in ['mean', 'min_val', 'max_val', 'quantifier']:
|
||||
if not isinstance(data[main_key].get(sub_key), numbers.Number):
|
||||
rv = False
|
||||
break
|
||||
elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
|
||||
rv = True
|
||||
for main_key in [dht_22.KEY_HUMIDITY, dht_22.KEY_TEMPERATURE, dht_22.KEY_TIME]:
|
||||
if main_key not in data:
|
||||
rv = False
|
||||
break
|
||||
else:
|
||||
for sub_key in ['mean', 'min_val', 'max_val', 'quantifier']:
|
||||
if not isinstance(data[main_key].get(sub_key), numbers.Number):
|
||||
rv = False
|
||||
break
|
||||
if rv is False:
|
||||
logger.warning("Validation failed for message: prot_id=%s, service_id=%s, data_id=%s, data=%s", repr(prot_id), repr(service_id), repr(data_id), repr(data))
|
||||
return rv
|
||||
@ -172,19 +201,25 @@ class WetationFrameProt(gui.Wetation):
|
||||
elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
||||
return
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
|
||||
logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
||||
txt_pressure = '- hPa'
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
self.in_pressure.SetLabel(txt_pressure)
|
||||
else:
|
||||
self.out_pressure.SetLabel(txt_pressure)
|
||||
self.Layout()
|
||||
return
|
||||
elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
|
||||
logger.debug('Resetting GUI for prot_id %d, service_id=%d, data_id=%d', prot_id, service_id, data_id)
|
||||
txt_temperature = '-.- °C'
|
||||
txt_humidity = '-.- %'
|
||||
txt_pressure = '- hPa'
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
self.in_temperature.SetLabel(txt_temperature)
|
||||
self.in_humidity.SetLabel(txt_humidity)
|
||||
self.in_pressure.SetLabel(txt_pressure)
|
||||
else:
|
||||
self.out_temperature.SetLabel(txt_temperature)
|
||||
self.out_humidity.SetLabel(txt_humidity)
|
||||
self.out_pressure.SetLabel(txt_pressure)
|
||||
self.Layout()
|
||||
return
|
||||
logger.warning("Unknown response with no valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
||||
@ -199,35 +234,49 @@ class WetationFrameProt(gui.Wetation):
|
||||
self.gate_close.Show(True)
|
||||
self.gate_position.SetValue(int(data * 100))
|
||||
self.Layout()
|
||||
return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
return
|
||||
elif service_id == garage_protocol.my_base_protocol_tcp.SID_EXECUTE_RESPONSE and data_id == garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE:
|
||||
return garage_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
return
|
||||
elif prot_id in [self.PROT_ID_IN, self.PROT_ID_OUT]:
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.CURRENT_ENVDATA:
|
||||
temp = data[dht_22.KEY_TEMPERATURE]
|
||||
if service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_BMP:
|
||||
data = helpers.continues_statistic_multivalue(**data)
|
||||
#
|
||||
# Current environmental data
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
wx.CallAfter(self.update_current_bmp_env_data, data, self.in_pressure)
|
||||
else:
|
||||
wx.CallAfter(self.update_current_bmp_env_data, data, self.out_pressure)
|
||||
return
|
||||
elif service_id == wetation_protocol.my_base_protocol_tcp.SID_READ_RESPONSE and data_id == wetation_protocol.my_base_protocol_tcp.ENVDATA_STATISTIC_DHT:
|
||||
data = helpers.continues_statistic_multivalue(**data)
|
||||
#
|
||||
# Current environmental data
|
||||
temp = data[dht_22.KEY_TEMPERATURE].mean
|
||||
if prot_id == self.PROT_ID_IN:
|
||||
if self.__max_temp_in__ is None or temp > self.__max_temp_in__:
|
||||
self.__max_temp_in__ = temp
|
||||
if self.__min_temp_in__ is None or temp < self.__min_temp_in__:
|
||||
self.__min_temp_in__ = temp
|
||||
wx.CallAfter(self.update_current_env_data, data, self.in_temperature, self.in_humidity, self.in_pressure, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
|
||||
wx.CallAfter(self.update_current_dht_env_data, data, self.in_temperature, self.in_humidity, self.in_temperature_min, self.in_temperature_max, self.__min_temp_in__, self.__max_temp_in__)
|
||||
else:
|
||||
if self.__max_temp_out__ is None or temp > self.__max_temp_out__:
|
||||
self.__max_temp_out__ = temp
|
||||
if self.__min_temp_out__ is None or temp < self.__min_temp_out__:
|
||||
self.__min_temp_out__ = temp
|
||||
wx.CallAfter(self.update_current_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_OKAY, None
|
||||
wx.CallAfter(self.update_current_dht_env_data, data, self.out_temperature, self.out_humidity, self.out_pressure, self.out_temperature_min, self.out_temperature_max, self.__min_temp_out__, self.__max_temp_out__)
|
||||
return
|
||||
logger.warning("Unknown response with valid data for prot_id %d, service_id=%d, data_id=%d", prot_id, service_id, data_id)
|
||||
return wetation_protocol.my_base_protocol_tcp.STATUS_SERVICE_OR_DATA_UNKNOWN, None
|
||||
|
||||
def update_current_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
|
||||
def update_current_bmp_env_data(self, env_data, pressure):
|
||||
pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE].mean)
|
||||
self.Layout()
|
||||
|
||||
def update_current_dht_env_data(self, env_data, temperature, humidity, pressure, temperature_min, temperature_max, value_min, value_max):
|
||||
if isinstance(value_min, numbers.Number) and isinstance(value_max, numbers.Number):
|
||||
temperature_min.SetLabel('%.1f' % value_min)
|
||||
temperature_max.SetLabel('%.1f' % value_max)
|
||||
temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE])
|
||||
humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY])
|
||||
pressure.SetLabel('%.0f hPa' % env_data[bmp_180.KEY_PRESSURE])
|
||||
temperature.SetLabel('%.1f °C' % env_data[dht_22.KEY_TEMPERATURE].mean)
|
||||
humidity.SetLabel('%.1f %%' % env_data[dht_22.KEY_HUMIDITY].mean)
|
||||
self.Layout()
|
||||
|
||||
def update_time(self):
|
||||
@ -236,6 +285,13 @@ class WetationFrameProt(gui.Wetation):
|
||||
self.Layout()
|
||||
|
||||
def gate_oc_evt(self, event):
|
||||
r = wx.MessageDialog(
|
||||
self,
|
||||
"Soll das Garagentor betätigt werden?",
|
||||
"Garage",
|
||||
wx.YES_NO | wx.NO_DEFAULT | wx.ICON_WARNING
|
||||
).ShowModal()
|
||||
if r == wx.ID_YES:
|
||||
logger.debug("Gate open/close request")
|
||||
self.__prot__[self.PROT_ID_GARAGE].send(garage_protocol.my_base_protocol_tcp.SID_EXECUTE_REQUEST, garage_protocol.my_base_protocol_tcp.OPEN_CLOSE_GATE, None)
|
||||
event.Skip()
|
||||
@ -284,7 +340,7 @@ class MyApp(wx.App):
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
report.appLoggingConfigure(os.path.dirname(__file__), config.LOGTARGET, config.loggers)
|
||||
report.appLoggingConfigure(os.path.dirname(__file__), config.LOGTARGET, config.loggers, fmt=config.formatter)
|
||||
#
|
||||
app = MyApp(0)
|
||||
app.frame.run()
|
||||
|
@ -1 +1 @@
|
||||
Subproject commit bc4808b313ecebba6511b82c801eeadd95e8a503
|
||||
Subproject commit e9c6321772df731317b5398b624e10ff509d489b
|
Loading…
x
Reference in New Issue
Block a user